Skip to main content

VxRail E Series Nodes

VxRail E Series Nodes

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1466 shown
1466 out of 1466 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  August 18, 2026 ID: 000205512

This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Updated:  July 31, 2026 ID: 000021527

Onboarding from vRealize Automation (vRA) 7 to vRA 8 raises a RuntimeException for a missing term or booleanClauses; issue caused by missing NSX-V account with NSX configuration in onboarding plan.
Updated:  August 19, 2026 ID: 000207283

Event code: VXR508PDR1102 This event code indicates "A predictive failure detected on drive <number>."
Updated:  August 19, 2026 ID: 000011768

Event code: VXR508PDR76 - This event code indicates "Copyback not possible as SAS or SATA mixing is not supported."
Updated:  August 19, 2026 ID: 000011766

VM migration fails as the switch (vDS) shows the port group on an unavailable network and reports down status. This occurs when the NSX‑T Data Center (NSX‑T) manager is removed, leaving N‑vDS down.
Updated:  August 19, 2026 ID: 000225929

Event code: VXR508PFM0002 This event code indicates "The value of <sensor name> is greater than the upper warning threshold."
Updated:  August 19, 2026 ID: 000011765

Event code: VXR508TMP0102 This event code indicates "The system board <name> temperature is greater than the upper warning threshold."
Updated:  August 19, 2026 ID: 000011764

Event code: VXR508STOR9 This event code indicates "No RAID controllers have been detected. Access to shared storage will not be available."
Updated:  August 19, 2026 ID: 000011763

Event code: VXR508TMP0106 This event code indicates "The memory module <number> temperature is less than the lower warning threshold."
Updated:  August 19, 2026 ID: 000011762

Event code: VXR508TMP0130 This event code indicates "The control panel temperature is less than the lower warning threshold."
Updated:  August 19, 2026 ID: 000011761

Event code: VXR508TMP0112 This event code indicates "The <name> temperature is less than the lower warning threshold."
Updated:  August 19, 2026 ID: 000011760

Event code: VXR508TMP0114 This event code indicates "The <name> temperature is greater than the upper warning threshold."
Updated:  August 19, 2026 ID: 000011759

Event code: VXR508TMP0202 This event code indicates "CPU <number> temperature is greater than the upper warning threshold."
Updated:  August 19, 2026 ID: 000011758

In VxRail release 8.0.230, VS‑760 nodes with a quad‑port Open Compute Project (OCP) NIC appear as a dual‑port NIC in the physical view; the model shows 4P but the visual layout hides two ports.
Updated:  August 18, 2026 ID: 000225461

ESXi hostd is randomly unresponsive, or the NSX transport shows "disconnected" status.
Updated:  August 18, 2026 ID: 000225630

Certificate manager shows “Unable to validate the chain of trust” and “INVALID_KEY” when a vCenter SSL certificate is installed, because the bundle misses an intermediate cert, breaking trust chain.
Updated:  August 18, 2026 ID: 000226729

This KB article provides instructions of how to upload files to a VxRail manager virtual machine.
Updated:  August 18, 2026 ID: 000224029

Event code: VXR508TMP0118 This event code indicates "The system inlet temperature is less than the lower warning threshold."
Updated:  August 14, 2026 ID: 000011757

Event code: VXR508SWC4008 This event code indicates "A firmware or software incompatibility detected between CMC 1 and CMC 2."
Updated:  August 14, 2026 ID: 000011756

Event code: VXR508PSU0044 This event code indicates "Cannot obtain status information from power supply <number>."
Updated:  August 14, 2026 ID: 000011755

Event code: VXR508STOR13 This event code indicates "Unable to set the operation mode of the newly inserted storage sled in slot <slot number> to Split Single or Split Dual Host, because the storage sled has only one PERC controller."
Updated:  August 14, 2026 ID: 000011754

Event code: VXR508STOR18 This event code indicates "A Shared Storage device is detected in slots other than Chassis Slots 5 and 6. This configuration is not currently supported."
Updated:  August 14, 2026 ID: 000011753

Event code: VXR508RDU0017 This event code indicates "The storage power redundancy is no longer available."
Updated:  August 14, 2026 ID: 000011752

Event code: VXR508SWC4006 This event code indicates "A firmware or software incompatibility detected between system BIOS in slot <number> and CMC."
Updated:  August 14, 2026 ID: 000011751

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  August 14, 2026 ID: 000185734

Event code: VXR508PWR1005 This event code indicates "The system performance degraded because of user-defined power capacity has changed."
Updated:  August 14, 2026 ID: 000011750

Event code: VXR508TMP0120 This event code indicates "The system inlet temperature is greater than the upper warning threshold."
Updated:  August 14, 2026 ID: 000011749

Event code: VXR508PDR7 This event code indicates "<physical disk> has degraded."
Updated:  August 14, 2026 ID: 000011748

Event code: VXR508PSU0005 This event code indicates "The power input for power supply <number> is outside of the allowable range, but it is attached to the system."
Updated:  August 14, 2026 ID: 000011747