DSA-2020-147: Dell Server Platform Security Advisory for the 2020.1 Intel Platform Updates (June 2020) - Intel SSD - CVE-2020-0527
Updated: May 06, 2026
ID: 000177610
Dell EMC guidance to mitigate risk and resolution for the iDRAC multiple vulnerabilities. For specific information about affected iDRAC versions and next steps to apply the updates, see this guide.
Updated: May 05, 2026
ID: 000177031
Event code: VXR500PDR1116
This event code indicates "Drive <number> is removed."
Updated: May 07, 2026
ID: 000013476
Event code: VXR500PST0130
This event code indicates "Memory is configured, but not usable."
Updated: May 07, 2026
ID: 000013475
Event code: VXR500PST0129
This event code indicates "Memory is detected, but is not configurable."
Updated: May 07, 2026
ID: 000013474
Event code: VXR500PDR20
This event code indicates "SMART configuration change for <PD Name>."
Updated: May 07, 2026
ID: 000013467
Event code: VXR500CTL12
This event code indicates "An invalid SAS configuration has been detected on <Controller name>. Details: <error message>"
Updated: May 07, 2026
ID: 000011714
Event code: VXR500ENC18
This event code indicates "Communication with <enclosure name> was lost."
Updated: May 07, 2026
ID: 000011713
Event code: VXR500PDR110
This event code indicates "The <PCIe solid state device name> reliability has degraded."
Updated: May 07, 2026
ID: 000011698
Event code: VXR500FAN0026
This event code indicates "The <sensor name> sensor detected an error with a value of <fan speed> RPM."
Updated: May 07, 2026
ID: 000011694
When the PS1010/PS1030 NVMe SSD or Samsung SATA 883/893 is installed, PSOD may occur during production or gathering operating system (OS) logs or TSR logs.
Updated: May 07, 2026
ID: 000251344
The VxRail upgrade on a cluster with vLCM enabled fails when it begins to upgrade the nodes. The error message received is "Failed getting host recommendation from DRS to enter maintenance mode for cluster."
Updated: May 07, 2026
ID: 000340543
Enabling Data-In-Transit Encryption on a vSAN Stretched Cluster causes the Witness Host to go into a partitioned state.
Updated: May 07, 2026
ID: 000217266
After upgrading vCenter from 7.0U3 to 8.0U1c, Skyline Health triggers alert vSAN Cluster Configuration Consistency.
Updated: May 07, 2026
ID: 000220633
The intent of this KB is to provide the proper course of action to take when the notified mystic code MYSTIC014062/VXR014062 takes place.
Updated: May 07, 2026
ID: 000032455
Event VXR500BAT0021 indicates that the battery has reached the end of its life.
Updated: May 07, 2026
ID: 000182374
CMOS Battery replacements for Basic Warranty contracts are under warranty through Dell for up to 1 year. This article outlines how to order and replace CMOS batteries once these batteries are no longer under warranty and replaced by Dell.
Updated: May 07, 2026
ID: 000227359
How to find the installed Security Technical Implementation Guidelines (STIG) version in a VxRail cluster.
Updated: May 07, 2026
ID: 000321694
VxRail license compliance prechecks before upgrading to 9.0.
Updated: May 06, 2026
ID: 000310965
vSphere 7.x and later
ESXi host experiences a Purple Screen of Death (PSOD) creates a Zdump core dump that is auto‑encrypted. This happens when the host is using Virtual Machine encryption.
Updated: May 06, 2026
ID: 000393489
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated: May 06, 2026
ID: 000414662
16G BOSS N1; logs VLT0204 (BOSS CPLD voltage out of range) or VLT0205. Affected Complex Programmable Logic Device (CPLD) versions: v1.2.6 on R660/R760 (VE-660 / VP/VS-760)
Updated: May 06, 2026
ID: 000390189
This is a vMotion issue, which fails due to general error or source host vMotion network error, even though vMotion VMkernel port is properly configured.
Updated: May 06, 2026
ID: 000225285
There are two common configuration changes that must be made to a VxRail cluster in order for virtual machines to be deployed with or upgraded to Windows 11.
Updated: May 06, 2026
ID: 000390644
The HTML 5 VxRail plugin was introduced in 4.7.100. Under certain circumstances, the VxRail plugin must be reinstalled. This article has the official attachments from VxRail Escalation Engineering for the VxRail 4.7.x, 7.x, and 8.x releases.
Updated: May 06, 2026
ID: 000182936
Dell VxRail remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: May 06, 2026
ID: 000456372
This article explains the different upgrade behaviors for various types of vSphere Distributed Switches (vDS) during VMware Cloud Foundation (VCF) on VxRail upgrade processes.
Updated: May 05, 2026
ID: 000423028
This guide details how to collect Node Image Management (NIM) logs in order to troubleshoot NIM reimage failures.
Updated: May 05, 2026
ID: 000389019
During initial cluster validation and host addition to an existing cluster, all affected nodes reported a NIC driver compliance error related to nic card.
Updated: May 05, 2026
ID: 000431782
Upgrading firmware on Kioxia CM6 NVMe drives to version 2.2.2 may lead to host instability.
Updated: May 05, 2026
ID: 000390943