Articole
Intrare nevalidă. Vă rugăm să utilizați numai litere, cifre și orice caractere speciale, cu excepția <>)(%/;,=#-/*
30 din 197 afișate
197 din 197 afișate
This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Actualizat: May 23, 2026
ID: 000349619
This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Actualizat: May 23, 2026
ID: 000349127
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Actualizat: May 23, 2026
ID: 000333712
Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Actualizat: May 23, 2026
ID: 000333265
R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Actualizat: May 23, 2026
ID: 000321587
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Actualizat: May 23, 2026
ID: 000311902
The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
Actualizat: May 23, 2026
ID: 000308774
During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
Actualizat: May 22, 2026
ID: 000278171
Performing a "yum update" check for Red Hat Enterprise Linux or SuSE Linux for Enterprise Servers updates may fail due to improper iDRAC RPM in the Dell YUM repository on linux.dell.com.
Actualizat: May 22, 2026
ID: 000262378
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Actualizat: May 22, 2026
ID: 000256907
DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
Actualizat: May 22, 2026
ID: 000251806
CPUs can be perceived to be hot while server is idle.
Actualizat: May 22, 2026
ID: 000250878
Various Dell enterprise products behave unexpectedly if IPMI is intentionally disabled from communicating between the operating system and iDRAC. This can be done by disabling the "In-band Management Interface" setting in BIOS System Security settings.
Actualizat: May 22, 2026
ID: 000247770
iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
Actualizat: May 21, 2026
ID: 000240336
The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Actualizat: May 21, 2026
ID: 000237298
PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
Actualizat: May 21, 2026
ID: 000236776
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
Actualizat: May 21, 2026
ID: 000227912
This article describes how to view and clear the system event log (SEL) in System Setup.
Actualizat: May 21, 2026
ID: 000226396
This article describes how to find the iDRAC's current MAC address.
Actualizat: May 21, 2026
ID: 000226214
During the power counter roll-over for utilization, the power counter rolls over before the rollover counter. This leads to an erroneous power spike which may throttle the server.
Actualizat: May 21, 2026
ID: 000225350
Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Actualizat: May 20, 2026
ID: 000224458
Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Actualizat: May 20, 2026
ID: 000223462
Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Actualizat: May 20, 2026
ID: 000222201
Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Actualizat: May 19, 2026
ID: 000221846
In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Actualizat: May 19, 2026
ID: 000221490
Network port enumeration on Windows Server 2022 with Dell network adapters may swap port designations.
Actualizat: May 19, 2026
ID: 000221408
After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Actualizat: May 19, 2026
ID: 000220891
The iDRAC is unable to connect to a Server Message Block (SMB) share when the optional "SMB3 share encryption" is enabled.
Actualizat: May 19, 2026
ID: 000219260
BIOS/CPLD or backplane firmware DUP may fail to update when attempted soon after iDRAC restart.
Actualizat: May 18, 2026
ID: 000216521
This article describes what can happen while collecting SupportAssist logs using iDRAC9 UI. The operation may result in an error, or incomplete logs may be collected.
Actualizat: May 17, 2026
ID: 000211904