Articole
Intrare nevalidă. Vă rugăm să utilizați numai litere, cifre și orice caractere speciale, cu excepția <>)(%/;,=#-/*
30 din 203 afișate
203 din 203 afișate
This article explains how to create and import an iDRAC certificate.
Actualizat: May 28, 2026
ID: 000120158
This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Actualizat: May 25, 2026
ID: 000136481
This document answers questions about SupportAssist Enterprise.
Actualizat: May 27, 2026
ID: 000060848
During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
Actualizat: May 26, 2026
ID: 000278171
The below article is a workaround mechanism to recover PowerEdge systems from critical log entry "SWC5008 Unable to access Front LED Panel because of a hardware error condition" for a few versions of the iDRAC.
Actualizat: May 25, 2026
ID: 000205597
The CTL137 event is new to iDRAC code 4.xx.xx.xx. The CTL137 event exist to notify the end user that the iDRAC lost communication with an endpoint device within the system.
Actualizat: May 25, 2026
ID: 000182797
PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
Actualizat: May 24, 2026
ID: 000417881
Server BIOS Update Guidelines for Microsoft Secure Boot Certificates are provided in this article.
Actualizat: May 24, 2026
ID: 000402373
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Actualizat: May 24, 2026
ID: 000381662
This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Actualizat: May 23, 2026
ID: 000349619
This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Actualizat: May 23, 2026
ID: 000349127
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Actualizat: May 23, 2026
ID: 000333712
Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Actualizat: May 23, 2026
ID: 000333265
R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Actualizat: May 23, 2026
ID: 000321587
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Actualizat: May 23, 2026
ID: 000311902
The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
Actualizat: May 23, 2026
ID: 000308774
Performing a "yum update" check for Red Hat Enterprise Linux or SuSE Linux for Enterprise Servers updates may fail due to improper iDRAC RPM in the Dell YUM repository on linux.dell.com.
Actualizat: May 22, 2026
ID: 000262378
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Actualizat: May 22, 2026
ID: 000256907
DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
Actualizat: May 22, 2026
ID: 000251806
CPUs can be perceived to be hot while server is idle.
Actualizat: May 22, 2026
ID: 000250878
Various Dell enterprise products behave unexpectedly if IPMI is intentionally disabled from communicating between the operating system and iDRAC. This can be done by disabling the "In-band Management Interface" setting in BIOS System Security settings.
Actualizat: May 22, 2026
ID: 000247770
iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
Actualizat: May 21, 2026
ID: 000240336
The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Actualizat: May 21, 2026
ID: 000237298
PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
Actualizat: May 21, 2026
ID: 000236776
Attempts to update the Broadcom NetXtreme 5719 and 5720 Network Interface Card (NIC) using the .bin file with sudo in Linux results in an 'Inventory Collection Failure' error.
Actualizat: May 21, 2026
ID: 000228045
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
Actualizat: May 21, 2026
ID: 000227912
Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Actualizat: May 21, 2026
ID: 000227227
This article describes how to view and clear the system event log (SEL) in System Setup.
Actualizat: May 21, 2026
ID: 000226396
This article describes how to find the iDRAC's current MAC address.
Actualizat: May 21, 2026
ID: 000226214
During the power counter roll-over for utilization, the power counter rolls over before the rollover counter. This leads to an erroneous power spike which may throttle the server.
Actualizat: May 21, 2026
ID: 000225350