This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Actualizat: January 12, 2026
ID: 000205512
This article provides links to PowerFlex software technical documentation.
Actualizat: January 09, 2026
ID: 000210475
Nodes are failing to PXE boot during deployment when Intel X710 NICs are present.
Actualizat: January 13, 2026
ID: 000195206
Even though the VLT enabled topology provides a loop-free environment in the VLT domain, some non-VLT member ports can end up in a loop scenario. Rapid spanning tree protocol (RSTP) and rapid per-VLAN spanning tree+ (RPVST+) modes of spanning tree protocol in VLT are supported to provide a solution for this scenario. Depending on the network topology, the primary node of the VLT domain can be designated as the root bridge.
Actualizat: January 13, 2026
ID: 000317735
Dell Virtual Link Trunking allows Layer 2 information to be shared across the two nodes. For this purpose, the same VLT domain-id should be configured on both VLT nodes. For rapid convergence and optimal service, the same VLT MAC address should be configured on both the nodes using the vlt-mac command (optional). In the absence of vlt-mac configuration, if the primary VLT node goes down, the VLT port channel on the secondary node flaps, causing slight traffic disruption.
Actualizat: January 13, 2026
ID: 000317732
Compute Only node upgrade fails with the error BIOS_FIRMWARE_TYPE WARNING: Legacy boot detected ESXi servers running legacy BIOS are encouraged to move to Unified Extensible Firmware Interface (UEFI)
Actualizat: January 12, 2026
ID: 000317135
This article explains how to Resynchronize a Compliance file or OS repository that is in an error state.
Actualizat: January 12, 2026
ID: 000383240
Procedure to update firmware to mitigate an issue of NVDIMM batteries losing charge on PowerFlex Rack and Appliance (R650, R750) nodes.
Actualizat: January 12, 2026
ID: 000228450
This article explains how to Standardizing Data VLAN Tagging After PFxM Upgrade and OS Conversion.
Actualizat: January 12, 2026
ID: 000406776
If a user attempts to deploy multiple volumes that exceed the available space, the request may not be blocked by PowerFlex Manager. If it is not blocked, the deployment fails and the volumes are in an error state.
Actualizat: January 10, 2026
ID: 000194856
By default, 14G SO nodes are configured to go to sleep to save power when idle. In the sleep state, when PowerFlex Manager issues IOs the response time is impacted while it wakes up. It is possible to set a parameter that does not allow the CPU to go to sleep but that setting will revert back to the default after a service upgrade.
Actualizat: January 10, 2026
ID: 000194768
This article explains when it is safe to ignore PowerFlex UI non-compliance when hardware component updates are necessary. The compliance flag in PFxM is a best-practice target matrix. If support and engineering guide the customer community to update hardware to fix issues in the field, such as stated in a KB article, Dell Technical Advisory (DTA), or Dell Security Advisory (DSA), deviation is allowed, supported, and acceptable.
Actualizat: January 09, 2026
ID: 000227433
Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Actualizat: January 09, 2026
ID: 000185734
This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
Actualizat: January 09, 2026
ID: 000143247
Deployment of a CO service with PowerFlex Manager 3.6 or later with Intelligent Catalog 36_360_A02.zip may result in having some nodes be noncompliant. The Micron M.2 SATA devices for the BOSS card have firmware E003 instead of E012.
Actualizat: January 09, 2026
ID: 000191626
PFxM-3.5.1-5539 with 13G HC and SO services backed up and restored to 3.7.0-7773 loses the cached network connectivity data for 13G nodes. After the restore, the 13G SO service goes into a critical and error state.
Actualizat: January 09, 2026
ID: 000189981
PowerFlex Manager installs operating systems during new service deployment or node expansion with Partial Network Automation using iDRAC virtual media. Sometimes when LACP networking is used with Dell OS 10 switches OS installation failures can be seen depending on the switch cabling used.
Actualizat: January 09, 2026
ID: 000189241
Node credentials can be changed from the Resources page of PowerFlex Manager. As many nodes as wanted may be selected and updated, but if too many are selected it could cause timeout issues.
Actualizat: January 09, 2026
ID: 000188944
In PowerFlex Manager, a disruptive service upgrade fails if the SVM name in vCenter does not match its hostname.
Actualizat: January 09, 2026
ID: 000188940
Switch discovery fails if "enable" password is required to activate configure commands.
Actualizat: January 09, 2026
ID: 000188937
PowerFlex : Conflicting/duplicate IP block the PFxM service deployment and node expansions VXFM00222
This article gives the procedure to locate a conflicting/duplicate IP and resolve it by removing the conflicting/duplicate IP.
Actualizat: January 09, 2026
ID: 000205922
During deployment, an existing SO service failed with the message "Could not connect to the SDS xxx over SSH due to a timeout. (VXFM00665)" All connectivity between PFxM appliance, gateway, and gateway to SDS data IPs is working and manual SSH was working.
Actualizat: January 09, 2026
ID: 000188625
This article describes about how to expand a service when all networks are not mapped to the service.
Actualizat: January 09, 2026
ID: 000187511
The host is stuck entering maintenance mode for a long time with no error.
Actualizat: January 09, 2026
ID: 000180477
PowerFlex: How to soft reset iDRAC 13G &14G
Actualizat: January 09, 2026
ID: 000019789
After upgrading the PowerFlex Management Platform from 4.0.0-161 to hotfix 4.0.0.1-169, the Resource Group Compliance Report shows no software components in the PowerFlex Manager UI.
Actualizat: January 09, 2026
ID: 000203532
PowerFlex Manager Platform (PFMP) crashes after restarting network services using "systemctl restart network."
Actualizat: January 09, 2026
ID: 000202162
When deploying a Storage-Only Resource Group on PowerFlex 5.x, the deployment wizard fails at IP reservation with error IDENTITYPOOLMANAGER.3004. The root cause is IP pools sized only for the storage nodes, without accounting for the additional MDM virtual IPs required by the deployment.
Actualizat: January 08, 2026
ID: 000412601
PowerFlex After the Motherboard is replaced, the node shows R740xd not VxFlex-R740xd in iDRAC.
Actualizat: January 08, 2026
ID: 000081547
This article provides links to PowerFlex rack technical documentation.
Actualizat: January 08, 2026
ID: 000211966