文章
输入无效。请仅使用字母、数字和除 <>)(%/;,=#-/* 之外的任何特殊字符
已显示 30 个,共 216 个
已显示 216 个,共 216 个
本文提供有关 Dell Technologies PowerProtect Data Manager 备份一体机版本 5.19.1 的修补程序更新的信息。
更新: 八月 18, 2025
ID: 000333850
Security clock skew violation detected PPDMA DM5510 Alert Event File System (EVT-FILESYS-00025) indicates that the file system is disabled and cannot be re‑enabled until system time is corrected within the configured skew threshold.
更新: 一月 08, 2026
ID: 000404191
File system cannot start due to an internal condition (PPDMA DM5510 Alert Event File System 00017).
更新: 一月 08, 2026
ID: 000404190
PPDMA DM5510 (Power Protection Device Management Agent) reports alert EVT-ENVIRONMENT-00065: power supply module status shows AC and DC pass/fail. AC pass/DC fail → PSU failed, replace. AC fail/DC fail → input PSU unavailable, check cables/LED, replace with working unit; shut down if all PSUs alert. Contact Dell support if the issue persists.
更新: 一月 08, 2026
ID: 000404189
Secondary Link Control Card (LCC) module failed in Enclosure <Enclosure Number> due to <Cause>, generating error PPDMA DM5510 EVT-ENVIRONMENT-00060
更新: 一月 08, 2026
ID: 000404188
The Dell PowerProtect Data Management Appliance (PPDMA) DM5510 reported alert EVT-ENVIRONMENT-00059: the Input/Output (IO) personality module has failed in the specified enclosure, causing potential unexpected behavior; replace the module.
更新: 一月 08, 2026
ID: 000404186
A fault (PPDMA DM5510 EVT‑ENVIRONMENT‑00058) was detected in the I/O expansion module; the module failed in Enclosure <#> for cause <#>, potentially causing unexpected system behavior.
更新: 一月 08, 2026
ID: 000404185
PowerProtect Data Manager DM5510 收到消息“PDR13 A disk at <arg1> 重建失败。”
更新: 一月 08, 2026
ID: 000403203
CTL40 警报指示在读/写过程中出现多位错误。多比特错误通常意味着数据丢失;如果在写入过程中,肯定会丢失。更换控制器电池组中的双列直插式内存模块 (DIMM) 并从备份还原数据。
更新: 一月 08, 2026
ID: 000404178
PowerProtect Data Manager DM5510 收到消息“Device <arg1> 失败;PPDMA (PPDMA) DM5510 (DM5510) 警报 TMP7 (TMP7) <arg1> 报告故障;系统性能降级;请更换设备。
更新: 一月 08, 2026
ID: 000403218
PowerEdge: Fan Failure Alert EVT-ENVIRONMENT-00057 - Identify Failed Fan and Replace.
更新: 一月 08, 2026
ID: 000404184
Correctable errors exceeded the critical threshold on Enclosure <Enclosure ID>, Field Replaceable Unit (FRU) <ID>. Symptom: PPDMA DM5510 Alert EVT-ENVIRONMENT-00054 Cause: may indicate hardware failure.
更新: 一月 08, 2026
ID: 000404182
A Dual inline Memory Module (DIMM) failure triggers a PPDMA DM5510 Alert CTL47 single‑bit Error Correcting Code (ECC) error. This can cause data loss or corruption; replace the DIMM immediately (it is part of the controller battery pack).
更新: 一月 08, 2026
ID: 000404180
A Single-bit Error Correcting Code (ECC) error shows the specified Dual inline Memory Module (DIMM) is critically degraded; data loss or corruption may occur. Replace the DIMM immediately; it is part of the controller battery pack.
更新: 一月 08, 2026
ID: 000404179
PowerProtect Data Manager DM5510 收到错误“FAN1002 <arg1> 失败了;机柜检测到风扇故障,运行状态欠佳;请联系戴尔客户支持。”
更新: 一月 08, 2026
ID: 000403217
PowerProtect Data Manager DM5510 收到错误“PDR57:坏块表 <arg1> 已满,无法记录数据块 <arg2>”的输出。将数据块标记为无效的不可恢复的介质错误会导致此问题。通过备份数据、重新初始化磁盘和从备份还原来解决问题。
更新: 一月 08, 2026
ID: 000403209
在电源上检测到风扇故障 <arg1>。
更新: 一月 08, 2026
ID: 000403171
错误PDR1001表示驱动器上出现故障 <arg1> 在磁盘驱动器托架中 <arg2>。控制器已将磁盘脱机。卸下并重新拔插驱动器;如果系统仍处于离线状态,请根据产品文档联系戴尔客户支持。
更新: 一月 08, 2026
ID: 000403196
此问题不是由 Data Mover 本身引起的。这是由于客户端上的 NFSv4 身份映射行为导致的。
更新: 一月 08, 2026
ID: 000091436
Dell PowerProtect Data Manager Appliance (DM5500) remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
更新: 一月 07, 2026
ID: 000355635
作系统 (OS) 驱动器出现故障或即将发生故障,触发 PPDMA DM5510 警报 EVT-STORAGE-00037;系统处于严重状态,如果另一个作系统驱动器出现故障,将会关闭。更换或复制恢复出现故障的作系统驱动器。
更新: 一月 02, 2026
ID: 000404197
本文介绍 NVRAMRemoteBatteryFailure 警报的原因和解决方法(事件 ID:Data Domain 系统上的 EVT-NVRAM-00202);此警报表示 NVRAM 远程电池存在严重硬件故障,必须先解决该故障,然后才能访问文件系统。
更新: 一月 01, 2026
ID: 000042368
在 PowerProtect Data Manager 服务器上,名为 vmware-service 的服务无法启动。
更新: 十二月 24, 2025
ID: 000394493
本知识库文章包含使用用户界面 (UI) 和命令行创建和下载管理日志包的过程。
更新: 十二月 23, 2025
ID: 000212015
错误BAT0012指示磁盘驱动器托架的存储电池 <arg1> 在 Dell PowerEdge DM5510 上出现故障。一个可能的原因是 PowerEdge RAID 控制器 (PERC) 电池的散热相关故障。验证电池安装并查看系统日志中的温度事件。
更新: 十二月 23, 2025
ID: 000403228
PDR12 初始化失败;磁盘显示红色“X”,表示硬盘发生故障或损坏。更换故障磁盘,然后重新启动初始化。
更新: 十二月 23, 2025
ID: 000403199
在以下时间发生了不可恢复的磁盘介质错误 (PDR64) <arg1> 在重建或恢复作期间;更换磁盘。
更新: 十二月 23, 2025
ID: 000403213
PDR47 A 块打开 <arg1> 被控制器刺穿。
更新: 十二月 23, 2025
ID: 000403206
PDR63:损坏的磁盘存储块 <arg1> 无法在写入作期间重新分配,从而阻止完成并可能导致数据丢失和冗余丢失。
更新: 十二月 23, 2025
ID: 000403212
错误 PDR73 Copyback failed from <arg1> 重定向到 <arg2> 表示回写作中涉及的硬盘驱动器失败;更换磁盘,然后重试此作。
更新: 十二月 23, 2025
ID: 000403215