文章
输入无效。请仅使用字母、数字和除 <>)(%/;,=#-/* 之外的任何特殊字符
已显示 30 个,共 765 个
已显示 765 个,共 765 个
本文提供了 PowerFlex 软件技术文档的链接。
更新: 一月 09, 2026
ID: 000210475
本文提供 PowerFlex 机架技术文档的链接。
更新: 一月 08, 2026
ID: 000211966
If a user attempts to deploy multiple volumes that exceed the available space, the request may not be blocked by PowerFlex Manager. If it is not blocked, the deployment fails and the volumes are in an error state.
更新: 一月 10, 2026
ID: 000194856
默认情况下,14G SO 节点配置为在空闲时进入睡眠状态以节省电量。在睡眠状态下,当 PowerFlex Manager发出 IO 时,响应时间会在唤醒时受到影响。 可以设置不允许 CPU 进入睡眠状态的参数,但在服务升级后,该设置将恢复为默认值。
更新: 一月 10, 2026
ID: 000194768
This article explains when it is safe to ignore PowerFlex UI non-compliance when hardware component updates are necessary. The compliance flag in PFxM is a best-practice target matrix. If support and engineering guide the customer community to update hardware to fix issues in the field, such as stated in a KB article, Dell Technical Advisory (DTA), or Dell Security Advisory (DSA), deviation is allowed, supported, and acceptable.
更新: 一月 09, 2026
ID: 000227433
This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
更新: 一月 09, 2026
ID: 000143247
Deployment of a CO service with PowerFlex Manager 3.6 or later with Intelligent Catalog 36_360_A02.zip may result in having some nodes be noncompliant. The Micron M.2 SATA devices for the BOSS card have firmware E003 instead of E012.
更新: 一月 09, 2026
ID: 000191626
PFxM-3.5.1-5539 with 13G HC and SO services backed up and restored to 3.7.0-7773 loses the cached network connectivity data for 13G nodes. After the restore, the 13G SO service goes into a critical and error state.
更新: 一月 09, 2026
ID: 000189981
PowerFlex Manager installs operating systems during new service deployment or node expansion with Partial Network Automation using iDRAC virtual media. Sometimes when LACP networking is used with Dell OS 10 switches OS installation failures can be seen depending on the switch cabling used.
更新: 一月 09, 2026
ID: 000189241
Node credentials can be changed from the Resources page of PowerFlex Manager. As many nodes as wanted may be selected and updated, but if too many are selected it could cause timeout issues.
更新: 一月 09, 2026
ID: 000188944
在 PowerFlex Manager 中,如果 vCenter 中的 SVM 名称与其主机名不匹配,则中断性服务升级将失败。
更新: 一月 09, 2026
ID: 000188940
Switch discovery fails if "enable" password is required to activate configure commands.
更新: 一月 09, 2026
ID: 000188937
PowerFlex : Conflicting/duplicate IP block the PFxM service deployment and node expansions VXFM00222
This article gives the procedure to locate a conflicting/duplicate IP and resolve it by removing the conflicting/duplicate IP.
更新: 一月 09, 2026
ID: 000205922
During deployment, an existing SO service failed with the message "Could not connect to the SDS xxx over SSH due to a timeout. (VXFM00665)" All connectivity between PFxM appliance, gateway, and gateway to SDS data IPs is working and manual SSH was working.
更新: 一月 09, 2026
ID: 000188625
This article describes about how to expand a service when all networks are not mapped to the service.
更新: 一月 09, 2026
ID: 000187511
The host is stuck entering maintenance mode for a long time with no error.
更新: 一月 09, 2026
ID: 000180477
PowerFlex: How to soft reset iDRAC 13G &14G
更新: 一月 09, 2026
ID: 000019789
将 PowerFlex 管理平台从 4.0.0-161 升级到热修复程序 4.0.0.1-169 后,资源组合规性报告在 PowerFlex Manager UI 中不显示任何软件组件。
更新: 一月 09, 2026
ID: 000203532
PowerFlex Manager Platform (PFMP) crashes after restarting network services using "systemctl restart network."
更新: 一月 09, 2026
ID: 000202162
PowerFlex 4.0 设计不允许每个 M&O 群集连接多个 PowerFlex 系统。如果客户想要更换或移除 PowerFlex 系统,则必须使用下面提到的过程。
更新: 一月 09, 2026
ID: 000201637
本文介绍了 ESXi 上的 hostd 服务无响应以及服务器对 vCenter 的管理作无响应的原因。发生这种情况的特定情形是在附加了 IO 筛选器的磁盘上执行 NFC作(如备份或复制作业)。
更新: 一月 09, 2026
ID: 000219067
无法在 PFxM UI 中执行 PFxM 备份作。
更新: 一月 09, 2026
ID: 000219106
This article guides through resolving inventory issues in the MDS Powerflex System caused by missing MDM IP addresses, as indicated by MDS kubectl logs and LIA logs on the MDMs.
更新: 一月 09, 2026
ID: 000220860
尝试在 PFMP UI 中升级 PowerFlex 数据块网关资源时无法访问 LIA 服务。
更新: 一月 09, 2026
ID: 000220920
RHEL 8.9 不支持 SDC。
更新: 一月 09, 2026
ID: 000221070
在最终部署屏幕中手动输入主机名和 IP 地址时,PowerFlex Manager 平台 (PFMP) 4.x UI 屏幕停止响应,并且光标消失。
更新: 一月 08, 2026
ID: 000220094
尝试添加现有资源组时,作业失败,并显示错误“安装后未完成”
更新: 一月 08, 2026
ID: 000219933
启动导入作业后,PowerFlex 管理平台 (PFMP) UI 不会立即显示任何正在运行的导入作业。
更新: 一月 08, 2026
ID: 000220134
虚拟机上配置 IPv6 的接口将服务置于生命周期模式 (LCM)。
更新: 一月 08, 2026
ID: 000219954
本文包含在观察到性能下降、每秒输入输出作数 (IOPS) 低、每秒 MB 数低或高延迟时,针对所有基于 PowerFlex 性能的问题采取的初始步骤。
更新: 一月 08, 2026
ID: 000220627