Ir al contenido principal
  • Realice pedidos rápida y fácilmente.
  • Vea los pedidos y haga el seguimiento del estado del envío.
  • Cree una lista de sus productos y acceda a ella
  • Gestione sus sitios, productos y contactos a nivel de producto de Dell EMC con la administración de empresa.

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2076

Description
Virtual disk Check Consistency failed.
Severity
Critical / Failure / Error
Cause and Action
Cause: AA physical disk included in the virtual disk failed or there is an error in the parity information. A failed physical disk can cause errors in parity information.

Action: Replace the failed physical disk. You can identify which disk has failed by locating the disk that has a red “ X” for its status. Rebuild the physical disk. When finished, restart the check consistency operation.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2081

SNMP Trap Numbers
1204

Valore este contenido

Acertado
Útil
Fácil de entender
¿Le ha resultado útil este artículo?
0/3000 characters
  Proporcione valoraciones (1-5 estrellas).
  Proporcione valoraciones (1-5 estrellas).
  Proporcione valoraciones (1-5 estrellas).
  Seleccione si el artículo le ha resultado útil o no.
  Los comentarios no pueden contener caracteres especiales: <>()\