Description
The BGI completed with uncorrectable errors.
Severity
Critical / Failure / Error
Cause and Action
Cause: The BGI task encountered errors that cannot be corrected. The virtual disk contains physical disks that have unusable disk space or disk errors that cannot be corrected.

Action: Replace the physical disk that contains the disk errors. Review other alert messages to identify the physical disk that has errors. If the virtual disk is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual disk is non-redundant, you may need to recreate the virtual disk after replacing the physical disk. After replacing the physical disk, run Check Consistency to check the data.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2081