Event ID — 2203

Description
A dedicated hot spare failed.
Severity
Warning/ Non-critical
Cause and Action
Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The disk may have failed or been removed. There may also be a bad or loose cable.

Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.

Related Alert Information
Clear Alert Number: None

Related Alert Number: 2048

Local Response Agent (LRA) Number: 2070