Ir al contenido principal
  • Realice pedidos rápida y fácilmente.
  • Vea los pedidos y haga el seguimiento del estado del envío.
  • Cree una lista de sus productos y acceda a ella
  • Gestione sus sitios, productos y contactos a nivel de producto de Dell EMC con la administración de empresa.

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2207

Description
The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks.
Severity
Warning / Non-critical
Cause and Action
Cause: The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in the virtual disk are using SATA technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails.

Action: Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2070

SNMP Trap Numbers
903

Valore este contenido

Acertado
Útil
Fácil de entender
¿Le ha resultado útil este artículo?
0/3000 characters
  Proporcione valoraciones (1-5 estrellas).
  Proporcione valoraciones (1-5 estrellas).
  Proporcione valoraciones (1-5 estrellas).
  Seleccione si el artículo le ha resultado útil o no.
  Los comentarios no pueden contener caracteres especiales: <>()\