Перейти к основному содержимому
  • Простое и быстрое размещение заказов
  • Просмотр заказов и отслеживание состояния доставки
  • Создание списка продуктов и доступ к нему
  • Управление узлами, продуктами и контактами уровня продуктов Dell EMC с помощью Company Administration.

Dell OpenManage Server Administrator Version 7.3 Command Line Interface Guide

Omreport Chassis Pwrmonitoring Or Omreport Mainsystem Pwrmonitoring

Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the properties of the system’s power consumption. The values display either in Watts or BTU/Hr based on the configuration. Type:
omreport chassis pwrmonitoring
or
omreport mainsystem pwrmonitoring
For each power monitoring profile in the system, values display for the following fields:
  • Power Consumption Status
  • Probe Name
  • Reading
  • Warning Threshold
  • Failure Threshold
  • Amperage: Location and Reading
  • Power Tracking Statistics
  • Energy Consumption
  • Measurement Start Time
  • Measurement Finish Time
  • Reading
  • System Peak Power
  • System Peak Amperage
  • NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system onwards that support PMBus and that have hot-swappable power supplies and not systems that have a fixed, non-redundant power supply installed.
  • NOTE: Power monitoring requires license to report the details. If the appropriate license is not installed or has expired, the system does not display the power consumption details of the system. For more information, see the Dell License Manager Guide at dell.com/openmanagemanuals.
  • NOTE: To maintain consistency across the commands, the output format of this command and the subsequent command levels has changed. So, you may have to change the user scripts as applicable.
An example output reporting power statistics in Watts is as follows:
Power Consumption Information
Power Consumption
Index : 1
Status : Ok
Probe Name : System Board Pwr Consumption
Reading : 539W
Warning Threshold : 994W
Failure Threshold : 1400 W
Amperage
PS1 Current 1 : 1.2 A
Power Headroom
System Instantaneous Headroom : 300 W
System Peak Headroom : 340 W
Power Tracking Statistics
Statistic : Energy consumption
Measurement Start Time : Thu May 28 11:03:20 2011
Measurement Finish Time : Fri May 28 11:05:46 2011
Reading : 5.9 KWH
Statistics : System Peak Power
Measurement Start Time : Mon May 18 16:03:20 2011
Peak Time : Wed May 27 00:23:46 2011
Peak Reading : 630 W
Statistics : System Peak Amperage
Measured Since : Mon May 18 16:03:20 2011
Read Time : Tue May 19 04:06:32 2011
Peak Reading : 2.5 A
  • NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, non-redundant power supply installed.