L-BIST is an enhancement to the single LED error code diagnostics and is automatically initiated during POST. L-BIST will check the LCD power rail. If there is no power being supplied to the LCD (i.e., the L-BIST circuit fails), the battery status LED will flash either an error code [2,8] or an error code [2,7].
NOTE: If L-BIST fails, LCD-BIST cannot function as no power will be supplied to the LCD.
How to invoke L-BIST Test:
Press the power button to start the system.
If the system does not start up normally, look at the battery status LED:
If the battery status LED flashes an error code [2,7], the display cable may not be connected properly.
If the battery status LED flashes an error code [2,8], there is a failure on the LCD power rail of the system board, hence there is no power supplied to the LCD.
For cases, when a [2,7] error code is shown, check to see if the display cable is properly connected.
For cases when a [2,8] error code is shown, replace the system board.