Prerequisites
Follow the safety guidelines listed in the Safety instructions.
Follow the procedure listed in Before working inside your system:
Power off the system and all attached peripherals.
Disconnect the system from the electrical outlet and disconnect the peripherals.
If applicable, remove the system from the rack.
Remove the system cover.
Remove the drive backplane cover.
If installed, remove the air shroud.
Remove the cooling fan.
Remove the side wall bracket.
Removing the left control panel:
Disconnect the control panel cable from the connector on the system board.
Remove the cable from the wall bracket.
Using the Phillips #1 screwdriver, remove the screws that secure the left control panel and the cable cover to the system.
Holding the cable, slide the left control panel out of the system.
NOTE: Observe the routing of the cable as you remove the right control panel from the system.
Installing the left control panel:
Align and slide the left control panel in the slot on the system.
Route the left control panel cable through the side wall of the system.
Connect the left control panel cable to the connector on the system board .
Align and slide the left control panel cable cover in the slot on the system.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
Using the Phillips #1 screwdriver, tighten the screws to secure the left control panel and the cable cover to the system.
Install the side wall bracket.
Install the cooling fan.
Install the drive backplane cover.
If removed, install the air shroud.
Follow the procedure listed in After working inside your system:
Replace the system cover.
If applicable, install the system into the rack.
Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.