For C6320P - PowerEdge C6300 ENCLOSURE FCB FW Update.

AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package contains the Fan Control Board FW update.
To view all drivers for your PowerEdge c6300, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

V0318-2017-11-15.exe | 239.58 KB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: Firmware Images
File Name: V0318-2017-11-15.exe
File Size: 239.58 KB
Format Description
To ensure the integrity of your download, please verify the checksum value.
MD5:
bcf20c00fcca1c30a817f78bd963f746
SHA1:
ca1661897ec302338b1871432cde23fabfca8f5b
SHA-256:
50ab0743419b368fa3f7ea921311ac12ce1eeb3ef7547f3bada2d781204dbad2

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
-N/A.

Enhancement:
-Enhanced PMON D3 command to prevent wrongly D9 decoding due to PSU noise coupling.
-Added FCB power/thermal event to be logged in iDRAC SEL.
Read More

Version

3.18, X00-00

Release date

07 Mar 2018

Download Type

Firmware

Category

Device Firmware

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.

Additional details

Show All | Hide All
1. Run the self extracting file and rename the updating file from FC0318.bin to FC0318.sc.
2. Check iDRAC IP, connect and login iDRAC to enable IPMI over LAN under iDRAC Settings>Network>IPMI Settings.
3. Download RACADM and IPMI tools from Dell.com.
4. Execute the script "racadm -r xxx.xxx.xxx.xxx -u Username -p Password update -f FC0318.sc" to update FCB FW under the folder with RACADM tool included. Where xxx.xxx.xxx.xxx is the iDRAC IP, Username and Password is the login name and Password.
5. When updating the FCB FW by the RACADM, at least 20 minutes is required after seeing the message "RAC1066: Firmware update for FC0318.sc" initiated successfully.
6. Execute the script "ipmitool -I lanplus -H xxx.xxx.xxx.xxx -U Username -P Password raw 0x30 0x12" to check the FW version under the folder with IPMI tool included.
7. Please check ReleaseNote_V0212(heavy).txt for more details.