Liteon 1100W PSU (PN: TFR9V) Firmware Package

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides the new firmware for power supplier and is supported on Liteon 1100W PSU (PN: TFR9V) running on the Windows and Linux operating systems.
To view all drivers for your PowerEdge C4130, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

Power_Firmware_GVC01_LN_00.24.35.BIN | 6.89 MB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: Update Package for Red Hat Linux
File Name: Power_Firmware_GVC01_LN_00.24.35.BIN
File Size: 6.89 MB
Format Description
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
208c0887606fc1c634119083e9709977
SHA1:
34bcb99750219a0f5cc2936e906314cecaa33202
SHA-256:
c650c047ede021dec408393ec32145825cebd5c6108fb84d7470a41faf513b0b

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Initial version
Read More

Version

00.24.35, 00.24.35

Release date

08 Sep 2014

Download Type

Firmware

Category

Power

Importance

Optional
Dell Technologies recommends reviewing this update to determine if it applies to your system. The update contains changes that impact only certain configurations or provides new features that may or may not apply to your environment.
View Important Information

File Format: A GnuPG file which contains a cryptographic signature
File Name: Power_Firmware_GVC01_LN_00.24.35.BIN.sign
File Size: 198 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c8072a19d81ffd2059a22cd498ceb490
SHA1:
0c7ccf471cd6863a36cf20ed0f4eb503542b56e1
SHA-256:
97b6f4d0de7b8b0fcbc16f7d52673ca2716ca71bae51ad2ac10273eceef205b5

File Format: Update Package for MS Windows 32-Bit
File Name: Power_Firmware_GVC01_WN32_00.24.35.EXE
File Size: 10.8 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
423e2a4ae0c224c1f04331a1dde3fe05
SHA1:
b337cfd0bdf3bd77ba4426917945d913f92dca5d
SHA-256:
f42c738b2b72af65e4c5b7947e442c70bcd5c0cb983cec5b81b36d4b929c0a81

File Format: Update Package for MS Windows 64-Bit.
File Name: Power_Firmware_GVC01_WN64_00.24.35.EXE
File Size: 18.73 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
1b08d06d4188a7e6b301c433a30dd242
SHA1:
9690afbbee74bae8bf3a23c974dc42b4ef838a81
SHA-256:
4f81a8456c157688ccbf2a07b241bee1394900fea4cef69958caecfa344583ba

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
IMPORTANT:
- After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
LiteOn 1100W PSU
PWR SPLY,1100W,RDNT,13G,LITEON
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.

Reboot will be required

Drivers help and tutorials