Restart requiredAUTO INSTALLEDThis file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
File Format:One or more self extracting disk images inside of a self extracting zip
File Name:9210-8i_14153000.exe
File Size:2.14 MB
Format Description
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
Sign in to Windows as an admin to use automatic scan. If your're already signed in as an admin and seeing this message, please reboot.Your system is managed by your IT admin and features might be limited.
Find more updates. Use SupportAssist to find all the latest driver updates for your device.
Fixes & Enhancements
1.When ios are running with cable break and make (b/w expander and drive),fault 8405 is hit 2.One of the inactive volumes member becomes offline/missing 3.0xC00C fault observed while doing Target Mode Aborts while running IOs 4.Incorrect data length reported for failed target mode transfers 5.RAID1 Volume fails to start resync when a hot plugged hot spare is available 6.On exiting PCIe Power management state, some configuration bits are not reset 7.Request Sense Command is showing incorrect data during Send Diagnostic foreground mode Command is issued. 8.pl: SATL: Sense data Valid bit and Information field may not be populated correctly 9.SAS2 IT - Phase 14 ?Allocation Length for SCSI MODE SENSE Command is not Handled Properly 10.SAS2 IT : Phase 14 : Cannot abort a background short Self test 11.Truncated Data is Obtained When SCSI Inquiry to VPD Page 0xB0 is Executed 12.Extra 60 Bytes of VPD Page Data is Provided When SCSI Inquiry to VPD Page 0x89 is Executed 13.SATL translation happens in firmware for a Persistent Reservation Command with SA=3 for a Invalid PLL 14.pl: SATL: Translation for foreground SELF TEST CODE field in Self Test Results log is incorrect 15. IT - Phase 14 ?When SATA Drive is Moved to Standby State via Mode Page(0x1a), ASC/ASCQ is Incorrect for REQUEST SENSE 16.SAS2 IT - Phase 14 ?Allocation Length for SCSI READ CAPACITY(16) Command is not Handled Properly 17.ManPage11 NVTime variable needs to be increased for all 2308 B0 and D1 HBAs with MRAM 18. PI error reported when PI error detected due to a frame CRC error 19. 4101 fault on link break during frame transmission 20.RAID1 volume fails to resync when compatible drive is available 21. DwsResetDef is unexpectedly modified to maximum value if Linear mode is utilized 22.Raid Accelerator IOs hang with injected Guard Errors or when running Multi-threaded IOs 23.Dell DCS request to make a new point release (based off the latest point release) to include 3G-lock and LED mapping fix
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Use sas2flash to flash the SAS controllers. please unzip the sas2flash update utility in attachment.
1. Copy all files to a folder. 2. Run "sas2flash -o -listsasadd" and record your SAS address. 3. Run "sas2flash -o -e 7" to erase the flash ROM. 4. Run "sas2flash -f 9210-8i_14153000.bin" to update the FW. 5. Run "sas2flash -b mptsas2.rom" to update the MPT BIOS. 6, run "sas2flash -o -sasadd xxxxxxxxxxxxxxxx"(xxxxxxxxxxxxxxxx the the SAS address you record in step 4.) 7. Reboot system.