LSI 9210 SAS RAID CARD 3G LED firmware

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
LSI 9210 SAS RAID CARD 3G LED firmware
To view all drivers for your PowerEdge C6220, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

9210-8i_14153000.exe | 2.14 MB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: One or more self extracting disk images inside of a self extracting zip
File Name: 9210-8i_14153000.exe
File Size: 2.14 MB
Format Description
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
b1ce4f509991301e304e800a8f267709
SHA1:
fecb0182728f1f333aa475583edd7a6f8696fbed
SHA-256:
f266f507c0f448cbc31816fa8e14d2e002ad377c17a6ff05d74cb235ce2e1903

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

1.When ios are running with cable break and make (b/w expander and drive),fault 8405 is hit
2.One of the inactive volumes member becomes offline/missing
3.0xC00C fault observed while doing Target Mode Aborts while running IOs
4.Incorrect data length reported for failed target mode transfers
5.RAID1 Volume fails to start resync when a hot plugged hot spare is available
6.On exiting PCIe Power management state, some configuration bits are not reset
7.Request Sense Command is showing incorrect data during Send Diagnostic foreground mode Command is issued.
8.pl: SATL: Sense data Valid bit and Information field may not be populated correctly
9.SAS2 IT - Phase 14 ?Allocation Length for SCSI MODE SENSE Command is not Handled Properly
10.SAS2 IT : Phase 14 : Cannot abort a background short Self test
11.Truncated Data is Obtained When SCSI Inquiry to VPD Page 0xB0 is Executed
12.Extra 60 Bytes of VPD Page Data is Provided When SCSI Inquiry to VPD Page 0x89 is Executed
13.SATL translation happens in firmware for a Persistent Reservation Command with SA=3 for a Invalid PLL
14.pl: SATL: Translation for foreground SELF TEST CODE field in Self Test Results log is incorrect
15. IT - Phase 14 ?When SATA Drive is Moved to Standby State via Mode Page(0x1a), ASC/ASCQ is Incorrect for REQUEST SENSE
16.SAS2 IT - Phase 14 ?Allocation Length for SCSI READ CAPACITY(16) Command is not Handled Properly
17.ManPage11 NVTime variable needs to be increased for all 2308 B0 and D1 HBAs with MRAM
18. PI error reported when PI error detected due to a frame CRC error
19. 4101 fault on link break during frame transmission
20.RAID1 volume fails to resync when compatible drive is available
21. DwsResetDef is unexpectedly modified to maximum value if Linear mode is utilized
22.Raid Accelerator IOs hang with injected Guard Errors or when running Multi-threaded IOs
23.Dell DCS request to make a new point release (based off the latest point release) to include 3G-lock and LED mapping fix
Read More

Version

14.15.30.00, 14.15.30.00

Release date

09 Apr 2013

Download Type

Firmware

Category

SAS RAID

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
View Important Information

File Format: A text file containing customer friendly fixes and enhancements information
File Name: EndUser LicenseAgreementType S_Rev. 040512.txt
File Size: 11.4 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format contains plain text which can be viewed with a standard text editor.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c2ffe409366d225552ac6ed58f206b58
SHA1:
88522584d2ed8711c12c71ae9e569116a26e7b0a
SHA-256:
b85aae437264a3f053c9efec6b47fa1ba6610de28b749a06c2fec3dfc87bf333

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
This is LSI9210 HBA card firmware supports 3G phy link limitation and LED mapping fix
LSI 9210-8I card
LSI HBA 9210-8i 3gb/s
Use sas2flash to flash the SAS controllers.
please unzip the sas2flash update utility in attachment.

1. Copy all files to a folder.
2. Run "sas2flash -o -listsasadd" and record your SAS address.
3. Run "sas2flash -o -e 7" to erase the flash ROM.
4. Run "sas2flash -f 9210-8i_14153000.bin" to update the FW.
5. Run "sas2flash -b mptsas2.rom" to update the MPT BIOS.
6, run "sas2flash -o -sasadd xxxxxxxxxxxxxxxx"(xxxxxxxxxxxxxxxx the the SAS address you record in step 4.)
7. Reboot system.

Reboot will be required