Dell PowerEdge C6220/ C6220 II BMC firmware 2.29

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides BMC Firmware and is supported on Dell PowerEdge PEC6220II running the following Operating System: Windows Server 2008 R2, 2012 and 2012 R2, Linux RHEL 6.3, RHEL6.4, SLES 11 update 2 and SLES 11 update 3, MS-DOS.
To view all drivers for your PowerEdge C6220, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

C6220-II_ESM_Firmware_VTDYR_LN32_2.29.BIN | 17.46 MB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: Update Package for Red Hat Linux
File Name: C6220-II_ESM_Firmware_VTDYR_LN32_2.29.BIN
File Size: 17.46 MB
Format Description
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
8cd2a2f431ef91769b2f2f56b809882c
SHA1:
da67f4ffd350f22bbc64d94d95825f17347b1e90
SHA-256:
89d5a36a06af61131143be2a6b74d64cdb8e3ec3ec38575cb702122700ab9116

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes
- Not Applicable

Enhancements
- Support new GPU card K40M.
Read More

Version

2.29, 2.29

Release date

18 Apr 2014

Download Type

Firmware

Category

Embedded Server Management

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
View Important Information

File Format: One or more self extracting disk images inside of a self extracting zip
File Name: PEC6220IIBMC229.exe
File Size: 148.58 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
d79cd1885155a5c8fb2af97120e77d03
SHA1:
db07a3e3c456997d92d64071350aa3026b58f806
SHA-256:
9fdcac95b117f9db278f7242b1e6a9679cd094d262d6bdc12931c88b7d08a0a5

File Format: A GnuPG file which contains a cryptographic signature
File Name: C6220-II_ESM_Firmware_VTDYR_LN32_2.29.BIN.sign
File Size: 189 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
f3dd4fbf576c7a13905d254aa1e8b647
SHA1:
aacd0def2033e7c9369f3e4e42884bf9f8767da1
SHA-256:
a97f3e15fd4062d2b987c5eee486282a0eb3fb59a8801e1efa27e445a4c23d43

File Format: A text file containing customer friendly fixes and enhancements information
File Name: EndUserLicenseAgreementTypeS_Rev.040512.txt
File Size: 11.4 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format contains plain text which can be viewed with a standard text editor.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c2ffe409366d225552ac6ed58f206b58
SHA1:
88522584d2ed8711c12c71ae9e569116a26e7b0a
SHA-256:
b85aae437264a3f053c9efec6b47fa1ba6610de28b749a06c2fec3dfc87bf333

File Format: Update Package for MS Windows 32-Bit
File Name: C6220-II_ESM_Firmware_VTDYR_WN32_2.29.EXE
File Size: 22.39 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
de9d61a7b4daaffbe5d8a1e80f8dd17c
SHA1:
3c3628ead4cd0f649b5883f28d811702c96ba63e
SHA-256:
d3bdb11cdd750d4a4d6d1523dcfd70ec5c6a68db08ba8f025d619422a9badf96

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
Limitation:
In this version, BMC added link status debunce function in share NIC for avoiding NIC link state boucing problem during DC cycle. BMC will skip NIC link status change within 5 seconds, so please do not replug LAN cable within 5 seconds.

Do not roll back to old version after you update to V1.14 already.
If you want to flash to old version, please use socflash.

BMC firmware might have version dependency with chassis firmware. Before update BMC firmware, please check related chassis FAN Controller Board firmware release package first.

KCSflash - use *.dcs for firmware update
NOTE: Since the KCS update utility may refer to some dynamic linked library files, KCSflash directory structure must be maintained to update BMC via KCS channel when it is extracted from the package.

=================================================================
Dos: Execute FBMC.bat in the folder, and utility will show the steps to upgrade BMC F/W.
=================================================================
Linux: Execute FBMC.sh in the folder, and utility will show the steps to upgrade BMC F/W.
=================================================================
Windows: Execute FBMC.bat in the folder, and utility will show the steps to upgrade BMC F/W.
=================================================================
Web Upgrade: Update via web by using *.dcs file under KCSflash/dos folder.
Note that Web upgrade is only for the current BMC is higher than V1.14.
=================================================================
Most usful parameter of DCSFWUD.EXE:
-e=value Specify enitity ID of image.
-f, -force Force reboot system or BMC without prompt user.
-o=value Specify the Install Options. Optional.
0 - Do not preserve config (default). (update BMC with default value)
1 - Preserve config. (update BMC with previous configuration)
-help Search for all parameter
=================================================================
Socflash - use allv***.bin for firmware update
Dell BMC Firmware
Download
1. Click 'Download File' to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.

This new version changed BMC shared NIC behavior from bonding mode to NCSI mode. That means you can specify the specific NCSI port (NIC1 or NIC2) as BMC shared NIC. Due to this change, if you're updating via KCS (fbmc.sh) instead of running DUP, it would perform "restore LAN setting to default" to enable this new feature. Please check your network setting after firmware update to confirm if there is any setting changed by this.

If you're updating BMC by DUP (without configuration preserved), Shared NIC2 MAC will be restored to default MAC address. It did not affect the normal operation on shared NIC1. However, if you would like to apply NIC2 as BMC shared NIC, you should program the MAC address again manually by IPMI command.

1. #Get reservation ID
ipmitool raw 0x30 0x01

2. #switch to NIC 2
ipmitool raw 0x30 0x03 0x[reservation ID from first step] 0x02 0x02 0x00 0x00 0x00 0x01 0x02

3. #Enter manufacturing test mode
ipmitool raw 0x06 0x05 0x64 0x52 0x45 0x4d 0x24 0x73 0x74 0x38

4. #Program MAC address for NIC 2 (assuming MAC address 00:11:22:33:44:56)
ipmitool 0x20 0x30 0x01 0x01 0x05 0x00 0x11 0x22 0x33 0x44 0x56
(The last 6 bytes are MAC address)

Reboot will be required