Article Number: 000142904
iDRAC users may notice that Dell EMC PowerEdge servers are not reporting VMware ESXi 6.5 or 6.7 System Host Name and Operating System fields in the iDRAC web and CLI interfaces. This behavior differs from the behavior previously witnessed on Dell EMC PowerEdge servers with VMware ESXi 6.0 and older.
To correct this behavior, you must enable CIM providers through ESXCLI and reboot the host.
esxcli system wbem set –e true
/etc/init.d/sfcbd-watchdog start
After reboot is complete, refresh the iDRAC and you should see the hostname loaded updated.
In newer builds of ESXi 6.5 and 6.7, enabling wbem will still not show the correct ESXi hostname in iDRAC. This is due to an intentional change by VMware where this functionality (writing hostname to BMC via inbox CIM providers) was removed. The future intention is for the hostd service to perform this function.
If enabling wbem (directions listed above) do not resolve the issue, the recommendation is to install either the Dell EMC iSM (iDRAC Service Module) or OpenManage Server Administrator vSphere Installation Bundle (VIB) for ESXi in the ESXi operating system.
VMware ESXi 6.5.X, VMware ESXi 6.7.X
iDRAC Service Module, iDRAC7, iDRAC8, iDRAC9, VMware ESXi 6.x, VMware ESXi 7.x