Dell EMC Unity: Re-imaging array after UnityClear array sanitize operation may cause rescue reason 0x0b00 BOOTFL and 0xFC0B0304 - Image failed integrity check

Summary: Re-imaging array after UnityClear array sanitize operation may cause rescue reason 0x0b00 BOOTFL and 0xFC0B0304 - Image failed integrity check

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

After Re-imaging a Unity array, it fails to boot on SPA with rescue reason 0x0b00 BOOTFL and SPB as rescue reason 0xFC0B0304 - Image failed integrity check

Cause

Attempting to re-image an array after a UnityClear Sanitize erase operation is causing the array not to boot and drives to report 03/31/80 errors and fbe_cli_physical_drive_display_info - DEATH REASON: (FBE_SAS_PHYSICAL_DRIVE_DEATH_REASON_UNEXPECTED_FAILURE). This indicates that the drive sanitize operation was interrupted and drives will report format corrupt 03/31/80 in response to the incomplete operation. This can happen if power was removed from the array or enclosure or drives were pulled while erase was in process. The error response from the drive is normal in this circumstance.

Resolution

Dell Support needs to rerun the UnityClear process to properly erase the drives and return them to normal operation and ready for re-imaging. UnityClear instructions are required to be followed completely ensuring drives are not powered off while the process is underway.

Example:
Logs from example KTrace:
16:21:09.110        118     7FE8687BD700 SASPMC 0 (BE0) OSW INFO Initiator check condition: mp context 0x10010109, SK = 0x03, ASC/Q = 0x3180
16:21:09.110          8     7FE8687BD700 WARN LIB  CPD  100C0 : fbe_cpd_shim_cdb_io_completion_callback_function  IO Status = 2 Payload: 420A8C18 CPD ID: 10010109
16:21:09.110         12     7FE8375FF700 INFO OBJ    14 DSK:0_0_4: fbe_base_physical_drive_io_fail fbe stat flag fail
16:21:09.110         11     7FE8375FF700 WARN OBJ    14 DSK:0_0_4: cc error, 03|31|80 Prt:10 Op:0x28 Lba:0x7000 Blks:0x1 Blba:0xffffffff pkt:0x7fe7420a87c0 svc:0 pri:2
16:21:09.110          1     7FE8375FF700 WARN OBJ    14 DSK:0_0_4: cc error , error:0x137
16:21:09.110          5     7FE8375FF700 INFO SERV ELOG  100C0 : 0x411c0002   Bus 0 Enclosure 0 Disk 4 CDB Check Condition. SN 97X0A0N5T3EE .