Summary: After a power outage, Management server reboot, or if the Management Console Service is restarted while the VPN is down, VPLEX reports "unreachable directors"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms


After a power outage or a cluster reboot, the Management server may not be able to see the VPlex directors and is unable to communicate with them.
In a Metro configuration the Management server of one cluster would report all directors are up while the other one is reporting unknown.

 

VPlexcli:/> cluster status
WARNING: There are unreachable directors: director-2-1-A director-2-1-B..
Connectivity may still have errors even if none are reported.
WARNING: Did not find corresponding wan-com port-group 'ip-port-group-0' on
cluster 'cluster-2'.
WARNING: Did not find corresponding wan-com port-group 'ip-port-group-1' on
cluster 'cluster-2'.

Cluster cluster-1
        operational-status:            ok
        transitioning-indications:
        transitioning-progress:
        health-state:                  ok
        health-indications:
        local-com:                     ok


wan-com: connectivity: NONE

ip-port-group-0 - FAIL - Failed to determine expected connectivity.
ip-port-group-1 - FAIL - Failed to determine expected connectivity.

Cause

After a Management server reboots or the Management Console Service is restarted while the VPN is down, the local vplexcli can sometimes lose connection with the remote and/or local directors and the directors need to be reconnected to the vplexcli. 

Resolution

         1. Confirm the VPN is up and the remote management server is reachable:
 

VPlexcli:/> vpn status
Verifying the VPN status between the management servers...
IPSEC is UP
Remote Management Server at IP Address xxx.xxx.xxx.xxx is reachable
Remote Internal Gateway addresses are reachable

Verifying the VPN status between the management server and the cluster witness server...
IPSEC is UP
Cluster Witness Server at IP Address 128.221.254.3 is reachable


          2. Confirm that metadata-volumes are connected and no there are issues with the BE array:
 

VPlexcli:/> ll clusters/cluster-1/system-volumes/

/clusters/cluster-1/system-volumes:
Name                                        Volume Type     Operational  Health  Active  Ready  Geometry  Component  Block     Block  Capacity  Slots
------------------------------------------  --------------  Status       State   ------  -----  --------  Count      Count     Size   --------  -----
------------------------------------------  --------------  -----------  ------  ------  -----  --------  ---------  --------  -----  --------  -----
LOGGING_VOL                          logging-volume  ok           ok      -       -      raid-1    2          2621440   4K     10G       -
LOGGING_VOL_2                     logging-volume  ok           ok      -       -      raid-1    2          5242880   4K     20G       -
META_DATA                          meta-volume     ok           ok      true    true   raid-1    2          20446976  4K     78G       64000
META_DATA_backup_2017Dec1  meta-volume     ok           ok      false   true   raid-1    1          20446976  4K     78G       64000
META_DATA_backup_2017Dec1  meta-volume     ok           ok      false   true   raid-1    1          20446976  4K     78G       64000


 
.         3.  Confirm that directors can be pinged and that you can ssh to them:
 
service@CLUSTER-2:~> ping 128.221.252.67
PING 128.221.252.67 (128.221.252.67) 56(84) bytes of data.
64 bytes from 128.221.252.67: icmp_seq=1 ttl=64 time=0.231 ms
64 bytes from 128.221.252.67: icmp_seq=2 ttl=64 time=0.189 ms


service@CLUSTER-2:~> ssh root@128.221.252.67
Last login: Mon Dec 11 16:58:29 2017 from 128.221.252.65
VPLEX
director-2-1-a:~ # 

 

4. List out the engines on the remote cluster as you will be prompted for the number of engines when you run the "configuration connect-remote-directors" command

 

VPlexcli:/> ll /engines/

/engines:
Name
----------

engine-2-1


 
         5. Connect the management server to either the local and remote directors (or both) using the " configuration connect-local-directors" and "configuration connect-remote-                  directors" commands. If the vplexcli can already see the local directors, then there is no need to run the configuration connect-local-directors command on the local cluster
    

VPlexcli:/> configuration connect-local-directors
Connected to Plex firmware director-1-1-A.

Connected to Plex firmware director-1-1-B.
 
VPlexcli:/> configuration connect-remote-directors
 
Please enter the number of engines present on the remote site (1, 2 or 4): 1

Connected to Plex firmware director-2-1-A.

Connected to Plex firmware director-2-1-B.

Affected Products

VPLEX Series

Products

VPLEX for All Flash, VPLEX GeoSynchrony, VPLEX Series, VPLEX Virtual Edition, VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000167328
Article Type: Solution
Last Modified: 03 مارس 2026
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.