Connectrix: Troubleshooting xbar Issues
Oversigt: This article describes how to troubleshoot xbar issues. Recently the field has been tasked with several mech replacements, that in the end, were not required.
Denne artikel gælder for
Denne artikel gælder ikke for
Denne artikel er ikke knyttet til et bestemt produkt.
Det er ikke alle produktversioner, der er identificeret i denne artikel.
Instruktioner
When an xbar error is seen, and the module goes down, and often a mechanical replacement is performed.
To troubleshoot an xbar issue, isolate the issue (provided the customer allows) between the xbar, supervisor, any line cards, and the chassis.
Perform isolation tasks in dealing with an xbar failure. The process calls for performing the following steps to isolate:
- Replace
xbar.
If the replacement fails, the issue lies outside thexbar. - With the replacement
xbarstill inserted, perform a system switchover (pending a maintenance window) to swap active and standby supervisors, and check xbar status. As they can be hot swapped, you can attempt to reinsert the oldxbarif the replacement still fails.
NOTE: It is critical to leave at least one
xbar in MDS 9500, and at least two in MDS 9700 switches, otherwise the system goes down. Do not remove all xbars.
2016 Jul 17 14:42:39 MDSswitch Jul 27 14:42:38 %KERN-2-SYSTEM_MSG: [25315862.942013] Switchover started by redundancy driver - kernel 2016 Jul 17 14:42:39 MDSswitch %SYSMGR-2-HASWITCHOVER_PRE_START: This supervisor is becoming active (pre-start phase)
- If the
xbaris still down and the switchover has occurred, collectshow tech-support detailsoutput and review the exception log. In many instances, the exception log shows errors on a line card from theCHICO ASIC.
exception information --- exception instance 7 ----
Module Slot Number: 7
Device Id : 145
Device Name : Sacramento Xbar ASIC
Device Errorcode : 0xc9100200
Device ID : 145 (0x91)
Device Instance : 00 (0x00)
Dev Type (HW/SW) : 02 (0x02)
ErrNum (devInfo) : 00 (0x00)
System Errorcode : 0x41ec006d SAC sync lost
Error Type : Warning
PhyPortLayer : Fibre Channel
Port(s) Affected :
Error Description : Lost sync on slot:7 asic:0 chico:19-->connected to-->Fab-1 link-01
DSAP : 0 (0x0)
UUID : 0 (0x0)
Time : Wed Jul 17 14:43:09 2016
(Ticks: 579900BD jiffies)
- If this occurs, remove and replace that line card, and then attempt to reinsert the
xbarafter the line card removal.
Berørte produkter
Connectrix MDS-Series HardwareProdukter
Connectrix MDS-9513, Connectrix MDS-9706, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-Series HardwareArtikelegenskaber
Artikelnummer: 000006063
Artikeltype: How To
Senest ændret: 20 mar. 2026
Version: 7
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.