Connectrix: Troubleshooting xbar Issues

Oversigt: This article describes how to troubleshoot xbar issues. Recently the field has been tasked with several mech replacements, that in the end, were not required.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Instruktioner

When an xbar error is seen, and the module goes down, and often a mechanical replacement is performed.

To troubleshoot an xbar issue, isolate the issue (provided the customer allows) between the xbar, supervisor, any line cards, and the chassis.

Perform isolation tasks in dealing with an xbar failure. The process calls for performing the following steps to isolate: 

  1. Replace xbar.
    If the replacement fails, the issue lies outside the xbar.
  2. With the replacement xbar still inserted, perform a system switchover (pending a maintenance window) to swap active and standby supervisors, and check xbar status. As they can be hot swapped, you can attempt to reinsert the old xbar if the replacement still fails.

NOTE: It is critical to leave at least one xbar in MDS 9500, and at least two in MDS 9700 switches, otherwise the system goes down. Do not remove all xbars.
 
2016 Jul 17 14:42:39 MDSswitch Jul 27 14:42:38 %KERN-2-SYSTEM_MSG: [25315862.942013] Switchover started by redundancy driver - kernel

2016 Jul 17 14:42:39 MDSswitch %SYSMGR-2-HASWITCHOVER_PRE_START: This supervisor is becoming active (pre-start phase)
  1. If the xbar is still down and the switchover has occurred, collect show tech-support details output and review the exception log. In many instances, the exception log shows errors on a line card from the CHICO ASIC.
exception information --- exception instance 7 ----
Module Slot Number: 7
Device Id         : 145
Device Name       : Sacramento Xbar ASIC
Device Errorcode  : 0xc9100200
Device ID         : 145 (0x91)
Device Instance   : 00 (0x00)
Dev Type (HW/SW)  : 02 (0x02)
ErrNum (devInfo)  : 00 (0x00)
System Errorcode  : 0x41ec006d SAC sync lost
Error Type        : Warning
PhyPortLayer      : Fibre Channel
Port(s) Affected  :
Error Description : Lost sync on slot:7 asic:0 chico:19-->connected to-->Fab-1 link-01
DSAP              : 0 (0x0)
UUID              : 0 (0x0)
Time              : Wed Jul 17 14:43:09 2016
                    (Ticks: 579900BD jiffies)
  1. If this occurs, remove and replace that line card, and then attempt to reinsert the xbar after the line card removal.  

Berørte produkter

Connectrix MDS-Series Hardware

Produkter

Connectrix MDS-9513, Connectrix MDS-9706, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-Series Hardware
Artikelegenskaber
Artikelnummer: 000006063
Artikeltype: How To
Senest ændret: 20 mar. 2026
Version:  7
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.