Data Domain: Disk Rescan Procedure

Oversigt: This article describes how to perform the disk rescan procedure on a Dell Data Domain system. The rescan operation manually polls all disk drives, forcing the system to reevaluate their state. While DDOS typically performs automatic scans, a manual rescan may be necessary if a replacement disk is not recognized. ...

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

Warning: This procedure applies only to single disk absent alerts. Do not use this method if multiple disks are reporting absent, as this may risk data loss.
 
Applies to:
  • All Data Domain systems
  • All software Versions

Symptoms

  • Autosupport alerts such as:
Err Code: STORAGE-00002 | STORAGE00002
Enclosure disk is absent and should be replaced
Disk in Absent State
  • Disk not recognized after replacement
  • Unable to bring the disk into a usable state (in-use or spare)

Årsag

Sometimes, DDOS may fail to detect a newly inserted disk due to:

  • Background processes interfering with disk discovery
  • Disk replaced too quickly before the system completed its internal checks
  • Transient hardware or communication issues

Løsning

Follow these steps to perform a disk rescan:

  1. Initial Rescan
    At the CLI prompt, run:

    • disk rescan
    • Wait for the command prompt to return.

    • If the disk is still reported as 'Absent', follow the steps below.
  2. Remove the Disk Drive
    Carefully remove the disk in question.

  3. Inspect the Disk

    • Check terminal connectors for debris or bent/damaged pins.
    • If pins are damaged, replace the disk.
  4. Wait for Detection Timeout

    • Allow 2 minutes for the SAS backplane to register the removal.
  5. Trigger Second Rescan
    At the CLI prompt, run:

    • disk rescan
    • Wait for the command prompt to return.

  6. Reinsert the Disk

    • Firmly reinsert the disk into its original slot.
    • Wait another 2 minutes for DDOS to detect the change.
  7. Verify Disk State

    • Run disk show hardware or disk show state to confirm the disk is now listed as in-use or spare.

Berørte produkter

Data Domain

Produkter

Data Domain
Artikelegenskaber
Artikelnummer: 000045237
Artikeltype: Solution
Senest ændret: 07 okt. 2025
Version:  3
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.