VxRail: Event Code: VXR500STOR374
Oversigt: Event VXR500STOR374 triggers due to a non-Unmap-capable drive being used for a rebuild operation.
Denne artikel gælder for
Denne artikel gælder ikke for
Denne artikel er ikke knyttet til et bestemt produkt.
Det er ikke alle produktversioner, der er identificeret i denne artikel.
Symptomer
Event code VXR500STOR374 indicates: Unable to use the non-Unmap-capable physical drive <physical drive friendly FQDD> for the rebuilding operation.
Årsag
The non-Unmap-capable hard drive identified in the message cannot be used for rebuilding operation.
Løsning
Ensure the drive used for rebuild operation is "Unmap-capable for virtual disk configuration" and then retry the operation.
To check if the drive is unmap-capable, run the following command at the Command-Line Interface (CLI):
racadm storage get pdisks -o -p UnmapCapabilityForVDConfig
Berørte produkter
VxRail, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N, VxRail E665, VxRail E665F, VxRail E665N
, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VE-670, VxRail VP-760, VxRail VP-7625, VxRail VP-770, VxRail VS-760
...
Artikelegenskaber
Artikelnummer: 000189233
Artikeltype: Solution
Senest ændret: 01 maj 2026
Version: 6
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices