VxRail: Event Code: VXR500STOR375

Oversigt: Attempting a copy-back operation on a non-unmap-capable drive triggers event code VXR500STOR375.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

Event code VXR500STOR375 indicates: Unable to use the non-unmap-capable physical drive <physical drive friendly FQDD> for the copy-back operation.

Årsag

The non-unmap-capable drive identified in the message cannot be used for copy-back operation.

Løsning

Verify the drive used for copy-back operation is "Unmap-capable for virtual disk configuration" and then retry the operation. 

To check if the drive is unmap-capable, run the following command at the Command-Line Interface (CLI):

racadm storage get pdisks -o -p UnmapCapabilityForVDConfig

Berørte produkter

VxRail, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N, VxRail E665, VxRail E665F, VxRail E665N , VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VE-670, VxRail VP-760, VxRail VP-7625, VxRail VP-770, VxRail VS-760 ...
Artikelegenskaber
Artikelnummer: 000189234
Artikeltype: Solution
Senest ændret: 01 maj 2026
Version:  6
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.