PowerStore: Clusters that have SAS Expansion Enclosures may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5
Oversigt: Clusters that have one or more SAS Expansion Enclosures, may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5.
Denne artikel gælder for
Denne artikel gælder ikke for
Denne artikel er ikke knyttet til et bestemt produkt.
Det er ikke alle produktversioner, der er identificeret i denne artikel.
Symptomer
The PowerStore nodes may unexpectedly reboot if these conditions are met:
- The cluster is on PowerStoreOS version 3.0.x, 3.2.x, or 3.5.x.
- There are one or more SAS expansion enclosures attached to any of the appliances in the cluster.
Årsag
The SAS drivers may time out due to a lock issue on the SAS controller.
This in turn causes a node unexpected reboot.
This in turn causes a node unexpected reboot.
Løsning
The issue is resolved in PowerStoreOS version 3.6 and above.