PowerStore: Clusters that have SAS Expansion Enclosures may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5

Oversigt: Clusters that have one or more SAS Expansion Enclosures, may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

The PowerStore nodes may unexpectedly reboot if these conditions are met:
  • The cluster is on PowerStoreOS version 3.0.x, 3.2.x, or 3.5.x.
  • There are one or more SAS expansion enclosures attached to any of the appliances in the cluster.

Årsag

The SAS drivers may time out due to a lock issue on the SAS controller.
This in turn causes a node unexpected reboot.

Løsning

The issue is resolved in PowerStoreOS version 3.6 and above.

Berørte produkter

PowerStore
Artikelegenskaber
Artikelnummer: 000203131
Artikeltype: Solution
Senest ændret: 29 jul. 2025
Version:  24
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.