PowerProtect Cyber Recovery: Error - "The storage interface name provided for multilink object is not valid"
Oversigt: Error when adding an interface to Multilink, stating that the object is invalid.
Denne artikel gælder for
Denne artikel gælder ikke for
Denne artikel er ikke knyttet til et bestemt produkt.
Det er ikke alle produktversioner, der er identificeret i denne artikel.
Symptomer
Customer is getting this error when trying to configure multi link.
ERROR: Failed to modify application:<CyberSense Server hostname> The storage interface name vethx.xxx provided for multilink object with storage ID xxxxx is not valid.
Årsag
Issue is due to a limitation with the number of interfaces on the vault Data Domain being more than 20.
Løsning
DD ../network/interfaces REST API only returns 20 interfaces by default, this has been extended to 100 in CR Release 19.13.0.3.
Release Notes/Installation guide for multilink configuration prerequisites must be followed to avoid further issues.
Berørte produkter
Cyber Recovery Series, CyberSenseArtikelegenskaber
Artikelnummer: 000214836
Artikeltype: Solution
Senest ændret: 16 okt. 2025
Version: 3
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.