PowerProtect Cyber Recovery: Panikfejl ved brug af CRCLI

Oversigt: Kan ikke starte CRCLI pga. panikfejl.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

Hvis du forsøger at starte CRCLI fra Cyber Recovery Shell, vises følgende fejl:
~ # crcli
panic: runtime error: index out of range [1] with length 1

goroutine 1 [running]:
cr/dev/crcli/libcli.verifyToken({0xc00010ac60, 0x154}, {0xc000021be0, 0x20, 0x20})
cr/dev/crcli/libcli/token_ircli.go:217 +0x34b
cr/dev/crcli/libcli.decryptCliToken({0xc00010ac60, 0x154})
cr/dev/crcli/libcli/token_ircli.go:228 +0xfa
cr/dev/crcli/libcli.readTokenFromFile()
cr/dev/crcli/libcli/token_ircli.go:259 +0x2bd
cr/dev/crcli/libcli.InternalApiCall({0x55f78cb320b8, 0x13})
cr/dev/crcli/libcli/token_ircli.go:84 +0x105
cr/dev/crcli/libcli.SetCRCapabilitiesEnable()
cr/dev/crcli/libcli/system_info.go:181 +0xd4
main.main()
cr/dev/crcli/climain.go:141 +0x6cf

Fra crcli.log(/opt/dellemc/cr/var/log/crcli)
[2023-06-12 16:37:41.077] [INFO] [crcli] [crlogging.go:173 SetLevel()] : Setting LogLevel to 3
[2023-06-12 16:37:41.077] [INFO] [crcli] [climain.go:119 main()] : =====================
[2023-06-12 16:37:41.077] [INFO] [crcli] [climain.go:120 main()] : crcli started: version=19.13.0.1-61
[2023-06-12 16:37:41.077] [DEBUG] [crcli] [climain.go:122 main()] : Entering
[2023-06-12 16:37:41.077] [DEBUG] [crcli] [system_info.go:179 SetCRCapabilitiesEnable()] : Entering
[2023-06-12 16:37:41.077] [DEBUG] [crcli] [token_ircli.go:81 InternalApiCall()] : Entering
[2023-06-12 16:37:41.077] [DEBUG] [crcli] [token_ircli.go:242 readTokenFromFile()] : Entering
[2023-06-12 16:37:41.077] [DEBUG] [crcli] [token_ircli.go:393 openHiddenFile()] : Entering
[2023-06-12 16:37:41.077] [DEBUG] [crcli] [token_ircli.go:376 getHiddenFile()] : Entering
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [token_ircli.go:389 getHiddenFile()] : Exiting
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [token_ircli.go:410 openHiddenFile()] : Exiting
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [token_ircli.go:225 decryptCliToken()] : Entering
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [token_ircli.go:209 verifyToken()] : Entering
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [encoding.go:49 DecodeString()] : Entering
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [encoding.go:57 DecodeString()] : Exiting
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [crcrypto.go:545 DecryptCFB()] : Entering
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [crcrypto.go:566 DecryptCFB()] : Exiting
[2023-06-12 16:37:41.078] [DEBUG] [crcli] [panic.go:884 gopanic()] : Exiting

Årsag

Dette problem skyldes, at tokenet ikke længere kan dekrypteres, hvilket tyder på, at tokenet ikke længere er gyldigt for den aktuelt loggede session.

Løsning

Udfør følgende trin for at løse problemet:
  1. Frakobl Cyber Recovery shell (ssh-forbindelse).
  2. Opret forbindelse tilbage til Cyber Recovery shell (ssh-forbindelse).
Disse trin tvinger til, at der genereres et nyt token, hvorefter adgangen til CRCLI lykkes.
Kontakt Dells tekniske support for at få flere oplysninger.