PowerEdge: UEFI Error in POST, HWC8010 or HWC8011

Oversigt: HWC8010 or HWC8011 UEFI errors in POST for iDRAC Hardware Configuration Validation typically occur due to firmware updates or the addition or removal of hardware components. Review system logs and investigate any recent changes before applying this solution. ...

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

  • HWC8010 or HWC8011 UEFI errors appear during POST, related to iDRAC Hardware Configuration Validation.
  • The system is unable to boot and displays the HWC8010 error code.
  • The error occurs after a firmware update or after adding or removing hardware components.
  • The error persists after rebooting the system.

Screenshot of POST error displaying the HWC8010 UEFI error code for iDRAC Hardware Configuration Validation

 

Årsag

  • Changes in the system's hardware or firmware configuration primarily cause the HWC8010 or HWC8011 UEFI error.
  • External factors such as environmental conditions or user actions can also contribute. For example, an interrupted firmware update or unauthorized hardware modifications can trigger the error.
  • Related HWC8010 or HWC8011 entries are recorded in the system event log and can help identify the cause.
  • The error frequently results from a firmware update alone, with no hardware changes made to the system.

Løsning

  1. Review the system logs to identify any recent firmware updates, hardware changes, or chassis openings.
  2. If a firmware update was initiated prior to the error, reboot to F2 > iDRAC Settings > Hardware Configuration Validation and change the option to Yes to accept the current configuration as valid, select Save and Exit.
  3. If the issue persists, contact Dell Support for further assistance.

BIOS F2 setup screen showing iDRAC Settings with the Hardware Configuration Validation option

 

UEFI Error HWC8010 or HWC8011 on POST

Duration: 0:43 (hh:mm:ss)
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

Berørte produkter

iDRAC9, Events and Error Codes, iDRAC9 - 6.xx Series, iDRAC9 - 7.xx Series, PowerEdge XR2, Poweredge C4140, PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge C6615, PowerEdge C6620, PowerEdge FC640, PowerEdge M640 , PowerEdge M640 (for PE VRTX), PowerEdge MX750c Compute Sled, PowerEdge MX760c Compute Sled, PowerEdge R450, PowerEdge R550, PowerEdge R650 Rack Server, PowerEdge R650xs Rack Server, PowerEdge R6515 Rack Server, PowerEdge R6525 Rack Server, PowerEdge R660 Rack Server, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625 Rack Server, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750 Rack Server, PowerEdge R750xa Rack Server, PowerEdge R750xs Rack Server, PowerEdge R7515 Rack Server, PowerEdge R7525 Rack Server, PowerEdge R760 Rack Server, PowerEdge R760XA Rack Server, PowerEdge R760xd2 Rack Server, PowerEdge R760xs Rack Server, PowerEdge R7615 Rack Server, PowerEdge R7625 Rack Server, PowerEdge R840 Rack Server, PowerEdge R860 Rack Server, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T150 Tower Server, PowerEdge T340, PowerEdge T350, PowerEdge T360 Tower Server, PowerEdge T440, PowerEdge T550 Tower Server, PowerEdge T560 Tower Server, PowerEdge T640, PowerEdge XR11, PowerEdge XR12, PowerEdge XR4510c, PowerEdge XR4520c, PowerEdge XR5610, PowerEdge XR7620, PowerEdge XR8610t, PowerEdge XR8620t ...
Artikelegenskaber
Artikelnummer: 000228171
Artikeltype: Solution
Senest ændret: 27 aug. 2026
Version:  8
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.