PowerProtect Data Manager: Kubernetes Cluster Discovery failed - IO Exception seuraavalla menetelmällä (stream was reset)

Summary: PowerProtect Data Manager Kubernetes Cluster Discovery failed - IO Exception during next method (stream was reset).

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Manager Kubernetes Cluster Discovery epäonnistui.
cndm.log-tiedostossa näkyy seuraava virhe:
2023-03-23T03:32:43.470Z ERROR [] [https-jsse-nio-127.0.0.1-8461-exec-3] [][][][TRACE_ID:9a9664af3ecde3e2;JOB_ID:9d8702e6e8798fea][] [c.e.b.c.d.s.CndmDiscoveryService.start(84)] -  discovery task failed
com.emc.brs.cndm.error.InternalServerErrorException: java.lang.RuntimeException: IO Exception during next method.
Caused by: java.lang.RuntimeException: IO Exception during next method.
Caused by: okhttp3.internal.http2.StreamResetException: stream was reset: INTERNAL_ERROR

Cause

Tuote toimii suunnitellusti.

Resolution

Siinä tapauksessa PowerProtect Data Managerin ja K8s-klusterin välissä on Nginx-palvelin. 

Muuta seuraavia asetuksia Nginx-kokoonpanotiedostossa /etc/nginx/default.d/server.conf
proxy_redirect off;
proxy_buffering ei pala;


PPDM Kubernetes Cluster Discovery on kunnossa tämän muutoksen jälkeen. 