PowerProtect Data Manager:Kubernetes Cluster Discovery failed - IO Exception during next method (stream was reset)
Summary: PowerProtect Data Manager Kubernetes Cluster Discovery failed - IO Exception during next method (stream was reset).
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PowerProtect Data Manager Kubernetesクラスターの検出に失敗しました。
cndm.logで次のエラーが発生します。
cndm.logで次のエラーが発生します。
2023-03-23T03:32:43.470Z ERROR [] [https-jsse-nio-127.0.0.1-8461-exec-3] [][][][TRACE_ID:9a9664af3ecde3e2;JOB_ID:9d8702e6e8798fea][] [c.e.b.c.d.s.CndmDiscoveryService.start(84)] - discovery task failed com.emc.brs.cndm.error.InternalServerErrorException: java.lang.RuntimeException: IO Exception during next method. Caused by: java.lang.RuntimeException: IO Exception during next method. Caused by: okhttp3.internal.http2.StreamResetException: stream was reset: INTERNAL_ERROR
Cause
製品は設計どおりに作動しています。
Resolution
これが確認された1つのケースでは、PowerProtect Data ManagerとK8sクラスターの間にNginxサーバーがあります。
Nginx設定ファイル/etc/nginx/default.d/server.conf
で次の設定を変更proxy_redirectオフにします。
proxy_bufferingオフ。
この変更後、PPDM Kubernetesクラスターの検出は正常です。
Nginx設定ファイル/etc/nginx/default.d/server.conf
で次の設定を変更proxy_redirectオフにします。
proxy_bufferingオフ。
この変更後、PPDM Kubernetesクラスターの検出は正常です。