Connectrix B-Series: DIAG-6004 messages in the RAS log

Summary: DIAG-6004 messages in the RAS log may not be indicative of an issue.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The DIAG-6004 message was recently added to log additional debug information.

In one case when a trunk primary port was decommissioned and reenabled, the customer saw that lots of DIAG-6004 messages continue to stream in the RAS log.

While not a cause for concern from an operational perspective, the messages can wrap the RAS log quickly making troubleshooting other issues more difficult.

2016/06/13-14:11:46:028238, [DIAG-6004], 2738279/0, CHASSIS, INFO, 5100, test_thread: tname porttestgetstatus fcn exits - PID: 2601, parameter.c, line: 1453, comp:insmod, ltime:2016/07/14-14:11:46:026694

2016/06/12-15:11:29:793102, [DIAG-6004], 8385/0, CHASSIS, INFO, 6505, test_thread: tname diagshow Calling fcn - PID: 30847, parameter.c, line: 1448, comp:insmod, ltime:2016/07/13-15:11:29:790743
 
2016/06/12-15:11:29:796263, [DIAG-6004], 8386/0, CHASSIS, INFO, 6505, test_thread: tname diagshow fcn exits - PID: 30847, parameter.c, line: 1453, comp:insmod, ltime:2016/07/13-15:11:29:795378
 
2016/01/28-09:10:17:434404, [DIAG-6004], 47815/0, SLOT 7 | CHASSIS, INFO, DCX, test_thread: tname diagshow fcn exits - PID: 985, parameter.c, line: 1453, comp:insmod, ltime:2016/02/29-09:10:17:434161

Cause

The DIAG-6004 message was recently added to log additional debug information and is not considered an indication of a problem.

Resolution

Issue addressed in FOS releases v7.4.1e, v8.0.2, and v8.1.0.

Affected Products

Connectrix

Products

Connectrix
Article Properties
Article Number: 000052146
Article Type: Solution
Last Modified: 05 Dec 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.