PowerScale OneFS 9.X.X:解決:已啟用位於下列位置的磁碟驅動器寫入快取

Summary: 在一或多個節點重新啟動后,使用者可能會看到一或多個節點的以下錯誤或類似內容。OneFS 停用寫入快取,以符合建議的磁碟驅動器設定。「已解決:磁碟驅動器在下列位置的寫入快取已啟用:機箱序號 JXXXXXXXXXXXX1、節點 4、SLED E、插槽 1、Type HDD、LNUM 0、序列 XXXXXXXX。」

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

變更的是節點已重新啟動。您可能不會看到所有磁碟驅動器的此訊息,可能只有整個叢集的一或兩個磁碟驅動器。

使用者會看到以下警示或類似資訊,並想知道造成此問題的原因,以及磁碟驅動器是否已損壞:
Resolved: The write-cache for the drive in the following location is enabled: Chassis Serial Number JXXXXXXXXXXXX1, Node 4, Sled E, Slot 1, Type HDD, LNUM 0, Serial XXXXXXXX. OneFS disabled the write-cache to comply with recommended drive settings. Replace the drive according to the instructions in the H400 Drive Replacement Guide.

注意:這僅在 Gen6 叢集上出現。

Cause

此問題是,根據預設,磁碟驅動器上的寫入快取已停用,而且在重新啟動期間,寫入快取似乎會變更為啟用。系統會回報此資訊(通常為外觀方面),而且在檢查「Write Cache Enabled」值時可以忽略此資訊。

此問題將在未來的 OneFS 版本中解決。Dell 工程團隊正在努力變更事件通知。

Resolution

執行以下命令以確認磁碟驅動器的狀態,以及磁碟驅動器寫入快取已停用:     
  1. 確認磁碟驅動器的狀態,並檢查是否有任何不健全的磁碟驅動器:       
# isi_for_array 'isi devices list | grep -iv "healthy" | grep -iv "L3"
  1. 檢查磁碟驅動器的寫入快取是否已停用:       
# camcontrol modepage da<drive da number> -m 8 -P 0
# camcontrol modepage da<drive da number>-m 8 -P 1
# camcontrol modepage da<drive da number>-m 8 -P 2
# camcontrol modepage da<drive da number>-m 8 -P 3

上述每個命令都會顯示值清單,如下所示: 
Cluster-8# isi_for_array -n4 camcontrol modepage da3 -m 8 -P 0
Cluster-4: IC: 0
Cluster-4: ABPF: 0
Cluster-4: CAP: 0
Cluster-4: DISC: 0
Cluster-4: SIZE: 0
Cluster-4: WCE: 0
Cluster-4: MF: 0
Cluster-4: RCD: 0
Cluster-4: Demand Retention Priority: 0
Cluster-4: Write Retention Priority: 0
Cluster-4: Disable Pre-fetch Transfer Length: 0
Cluster-4: Minimum Pre-fetch: 0
Cluster-4: Maximum Pre-fetch: 0
Cluster-4: Maximum Pre-fetch Ceiling: 0

Cluster-8# isi_for_array -n4 camcontrol modepage da3 -m 8 -P 1
Cluster-4: IC: 0
Cluster-4: ABPF: 0
Cluster-4: CAP: 0
Cluster-4: DISC: 0 Cluster-4: SIZE: 0
Cluster-4: WCE: 0
Cluster-4: MF: 0
Cluster-4: RCD: 0
Cluster-4: Demand Retention Priority: 0
Cluster-4: Write Retention Priority: 0
Cluster-4: Disable Pre-fetch Transfer Length: 0
Cluster-4: Minimum Pre-fetch: 0
Cluster-4: Maximum Pre-fetch: 0
Cluster-4: Maximum Pre-fetch Ceiling: 0
Please check the value associated with the WCE Parameter for each of the commands. If WCE is set to 0, then we can safely ignore and quiet the alert.
 
注意:步驟 2 的命令僅在 Gen6 硬體上執行

Affected Products

Isilon, Isilon A200, Isilon A2000, Isilon F800, Isilon F810, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600
Article Properties
Article Number: 000170338
Article Type: Solution
Last Modified: 29 May 2025
Version:  6