PowerScale OneFS 9.X.X:Resolved: 启用以下位置的驱动器的写入高速缓存
Summary: 在一个或多个节点重新启动后,用户可能会看到一个或多个节点的以下错误或类似内容。OneFS 禁用了写入高速缓存,以符合建议的驱动器设置。“已解决:启用以下位置的驱动器的写入高速缓存:机箱序列号JXXXXXXXXXXXX1、节点 4、底座 E、插槽 1、类型 HDD、LNUM 0、串行 XXXXXXXX。”
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
更改是节点重新启动。对于所有驱动器,您可能不会看到此消息,可能整个群集中只有一个或两个驱动器。
用户会看到以下警报或类似内容,并想知道导致该问题的原因以及驱动器是否损坏:
提醒:这仅在第 6 代群集上出现。
用户会看到以下警报或类似内容,并想知道导致该问题的原因以及驱动器是否损坏:
Resolved: The write-cache for the drive in the following location is enabled: Chassis Serial Number JXXXXXXXXXXXX1, Node 4, Sled E, Slot 1, Type HDD, LNUM 0, Serial XXXXXXXX. OneFS disabled the write-cache to comply with recommended drive settings. Replace the drive according to the instructions in the H400 Drive Replacement Guide.
提醒:这仅在第 6 代群集上出现。
Cause
该问题是,默认情况下,驱动器上的写入高速缓存处于禁用状态,并且在重新启动期间,写入高速缓存似乎已更改为已启用。系统报告此信息通常是表面性质的,可在检查“Write Cache Enabled”值时忽略。
这将在未来的 OneFS 版本中得到解决。戴尔工程团队正在努力更改事件通知。
这将在未来的 OneFS 版本中得到解决。戴尔工程团队正在努力更改事件通知。
Resolution
运行以下命令以确认驱动器的状态以及驱动器写入高速缓存已禁用:
上述每个命令都显示值列表,如下所示:
- 验证驱动器的状态,并检查是否有任何不正常运行的驱动器:
# isi_for_array 'isi devices list | grep -iv "healthy" | grep -iv "L3"
- 检查驱动器的写入高速缓存是否已禁用:
# camcontrol modepage da<drive da number> -m 8 -P 0 # camcontrol modepage da<drive da number>-m 8 -P 1 # camcontrol modepage da<drive da number>-m 8 -P 2 # camcontrol modepage da<drive da number>-m 8 -P 3
上述每个命令都显示值列表,如下所示:
Cluster-8# isi_for_array -n4 camcontrol modepage da3 -m 8 -P 0 Cluster-4: IC: 0 Cluster-4: ABPF: 0 Cluster-4: CAP: 0 Cluster-4: DISC: 0 Cluster-4: SIZE: 0 Cluster-4: WCE: 0 Cluster-4: MF: 0 Cluster-4: RCD: 0 Cluster-4: Demand Retention Priority: 0 Cluster-4: Write Retention Priority: 0 Cluster-4: Disable Pre-fetch Transfer Length: 0 Cluster-4: Minimum Pre-fetch: 0 Cluster-4: Maximum Pre-fetch: 0 Cluster-4: Maximum Pre-fetch Ceiling: 0 Cluster-8# isi_for_array -n4 camcontrol modepage da3 -m 8 -P 1 Cluster-4: IC: 0 Cluster-4: ABPF: 0 Cluster-4: CAP: 0 Cluster-4: DISC: 0 Cluster-4: SIZE: 0 Cluster-4: WCE: 0 Cluster-4: MF: 0 Cluster-4: RCD: 0 Cluster-4: Demand Retention Priority: 0 Cluster-4: Write Retention Priority: 0 Cluster-4: Disable Pre-fetch Transfer Length: 0 Cluster-4: Minimum Pre-fetch: 0 Cluster-4: Maximum Pre-fetch: 0 Cluster-4: Maximum Pre-fetch Ceiling: 0 Please check the value associated with the WCE Parameter for each of the commands. If WCE is set to 0, then we can safely ignore and quiet the alert.
提醒:步骤 2 的命令仅在第 6 代硬件上运行
Affected Products
Isilon, Isilon A200, Isilon A2000, Isilon F800, Isilon F810, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600Article Properties