Symptoms

When logging into the UI on a specific node, the following error is seen on the dashboard or end user license agreement notification:
error 6500

 

Cause

There are three ECS services responsible for UI login, stat, "ecsportalsvc," and "obcontrolsvc" - these have stale entries which are not allowing the UI to log in.

 

Resolution

On the concerning node, restart the stat, ecsportalsvc, and obcontrolsvc. There is no impact on restarting these services but it should be noted that any alerts generated on the UI on another node are now linked to these restarts:

 

Using service tools:

admin@node1:~> svc_node services restart -nw 10 -srv stat ecsportalsvc objcontrolsvc -n self
Starting utility inside a screen session

 

Confirm on the concerning node (rack 1 node 1) that the services have restarted and ensure that there are no services that are not running:

admin@node1:~> svc_node services -status
svc_node v1.2.1 (svc_tools v2.1.0)                 Started 2022-02-25 11:40:49

Node r1n1:
    Services running:
        fabric-agent

        blobsvc        (102925) Started: 2021-12-20 17:07:17      cm             (102859) Started: 2021-12-20 17:07:17
        coordinatorsvc (102843) Started: 2021-12-20 17:07:17      dataheadsvc    (102935) Started: 2021-12-20 17:07:17
        dtquery        (102951) Started: 2021-12-20 17:07:17      ecsportalsvc   (66505)  Started: 2022-02-25 11:31:08
        eventsvc       (102932) Started: 2021-12-20 17:07:17      georeceiver    (102950) Started: 2021-12-20 17:07:17
        metering       (102908) Started: 2021-12-20 17:07:17      objcontrolsvc  (69329)  Started: 2022-02-25 11:31:32
        resourcesvc    (102939) Started: 2021-12-20 17:07:17      rm             (102851) Started: 2021-12-20 17:07:17
        sr             (102905) Started: 2021-12-20 17:07:17      ssm            (102899) Started: 2021-12-20 17:07:17
        stat           (65535)  Started: 2022-02-25 11:30:55      storageserver  (102896) Started: 2021-12-20 17:07:17
        vnest          (102847) Started: 2021-12-20 17:07:17

    Services not running:
        <none>

 

Return to the ECS UI and you can log in without issue.

 

Affected Products

ECS

Products

ECS Appliance, ECS Appliance Gen 1, ECS Appliance Gen 2, ECS Appliance Gen 3
Article Properties
Article Number: 000196746
Article Type: Solution
Last Modified: 05 Mar 2024
Version:  8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.