AppSync: While attempting to add a new PowerMax to AppSync, a popup is recevied stating an exception in getDeviceMaskingGroups

Summary: A 10.1.0.2 PowerMax using U4P 10.1.0.5, which are the latest versions as of the writing of this article, is failing to add to AppSync.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

While adding the PowerMax and progressing to step 4 to specify groups and pools, a pop up error is received stating:
VMAX operation failed. Error: getDeviceMAskingGroups:: archwayexception:null
 
VMAX operation failed. Error: getDeviceMAskingGroups:: archwayexception:null

The AppSync Server log will show:
<date time>  ERROR [default task-1] [com.emc.archway.restapi.restresources.vmax.ManagedStorageSystemInstancesResource] [as-serv] [] 40f25299-1683-46ea-948c-5e7b51ee74d0->>> Exception Occurred: VmaxOperationException, Message: VMAX operation failed. Error: getDeviceMaskingGroups:: archwayexception :null

Cause

Software Bug

Resolution

A hotfix exists for this issue.
Note this article when calling in a service request.

Products

PowerMax
Article Properties
Article Number: 000225704
Article Type: Solution
Last Modified: 18 Sept 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.