PowerScale:Linux CEE 调试和日志收集

Summary: 如何在 Linux CEE Box 上启用 Common Event Enabler (CEE) 调试。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

在运行 Linux CEE 时,可以启用调试模式,以便收集更高级的数据以进行故障处理,请执行以下步骤:

复制配置文件以允许简单还原: 

#cp /opt/CEEPack/emc_cee_config.xml /opt/CEEPack/emc_cee_config.xml.bak

Edit the /opt/CEEPack/emc_cee_config.xml configuration file to set both debug and Verbose to 63.  
#vi /opt/CEEPack/emc_cee_config.xml

Under Configuration, find "Debug" and "Verbose" and change value to 63:
<Configuration>
    <CacheSize>100</CacheSize>
    <Debug>63</Debug>
    <HeartBeatIntervalSecs>10</HeartBeatIntervalSecs>
    <InstrIntervalSecs>60</InstrIntervalSecs>
    <NumberOfThreads>20</NumberOfThreads>
    <Verbose>63</Verbose>
    <HttpPort>12228</HttpPort>
    <DirDBPath></DirDBPath>
    <WatchDog>
      <RestartDelay>5</RestartDelay>
      <RestartCount>2</RestartCount>
      <ResetRestartCountAfter>86400</ResetRestartCountAfter>
    </WatchDog>
  </Configuration>
</CEEConfig>
Restart the CEE process: 

# /opt/CEEPack/emc_cee_svc restart
Shutting down EMC CEE Service:                             [  OK  ]
Starting EMC CEE Service: emc_cee.exe (pid 18902 18899) is running...

Debug is now enabled.  Trigger some auditable events on the cluster or monitor for the error we are troubleshooting then revert back to original. 

To revert back to original config: 

First, I like to make a copy of the debug config for future use: 
#cp /opt/CEEPack/emc_cee_config.xml /opt/CEEPack/emc_cee_config.xml.debug

Then Copy the original backup back to the main config and restart CEE again
#cp /opt/CEEPack/emc_cee_config.xml.bak /opt/CEEPack/emc_cee_config.xml
#/opt/CEEPack/emc_cee_svc restart

We want to then gather the log file /opt/CEEPack/emc_cee_svc.log and have that sent in for review.  

 
 

Additional Information

有关 Linux 上的 CEE 配置和使用说明,请按照随附 的“Linux 上的 Common Event Enabler” 文档进行作。

如果创建了以前制作的配置文件的调试副本,并且原始配置仍然存在,则可以将调试文件复制到主配置并重新启动服务(始终备份当前配置,如上所示):

#cp /opt/CEEPack/emc_cee_config.xml.debug /opt/CEEPack/emc_cee_config.xml
#/opt/CEEPack/emc_cee_svc restart

Affected Products

PowerScale OneFS

Products

PowerScale OneFS
Article Properties
Article Number: 000009293
Article Type: How To
Last Modified: 20 Nov 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.