ECS:getrackinfo 在 3.2.2 之後的變更
Summary: Getrackinfo 在 3.2.2 升級後變更。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
升級至 3.2.2.0 後,BMC/RMM 位址的 getrackinfo 顯示畫面會有所變更。
ECS 第 1 代和第 2 代 - BMC (通道 1) 和 RMM (通道 3)
ECS 第 3 代 - BMC (通道 1)
升級前:
命令:
# getrackinfo
範例:
Node private Node Public RMM Ip Address Id Status Mac Ip Address Mac Ip Address Node Name =============== ====== ====== ================= ================= ================= ================= ========= 192.168.219.1 1 MA 00:1e:67:fd:8e:9e xxx.xxx.xxx.xxx 00:1e:67:dd:c4:33 xxx.xxx.xxx.xxx provo-red 192.168.219.2 2 SA 00:1e:67:fd:7d:86 xxx.xxx.xxx.xxx 00:1e:67:df:fe:87 xxx.xxx.xxx.xxx sandy-red 192.168.219.3 3 SA 00:1e:67:fd:88:96 xxx.xxx.xxx.xxx 00:1e:67:d6:11:63 xxx.xxx.xxx.xxx orem-red 192.168.219.4 4 SA 00:1e:67:fd:7f:b6 xxx.xxx.xxx.xxx 00:1e:67:df:f6:53 xxx.xxx.xxx.xxx ogden-red
升級後:
Node private Node Public BMC
Ip Address Id Status Mac Ip Address Mac Ip Address Node Name
=============== ====== ====== ================= ================= ================= ================= =========
192.168.219.1 1 MA 00:1e:67:fd:8e:9e xxx.xxx.xxx.xxx 00:1e:67:dd:c4:33 xxx.xxx.xxx.xxx provo-red
192.168.219.2 2 SA 00:1e:67:fd:7d:86 xxx.xxx.xxx.xxx 00:1e:67:df:fe:87 xxx.xxx.xxx.xxx sandy-red
192.168.219.3 3 SA 00:1e:67:fd:88:96 xxx.xxx.xxx.xxx 00:1e:67:d6:11:63 xxx.xxx.xxx.xxx orem-red
192.168.219.4 4 SA 00:1e:67:fd:7f:b6 xxx.xxx.xxx.xxx 00:1e:67:df:f6:53 xxx.xxx.xxx.xxx ogden-red
ECS 第一 代和 第二代,上面顯示的 IP 組態是通道 3,也就是 RMM (公用 BMC)。
ECS Gen 3 此處顯示的 IP 組態為通道 1,也就是 BMC (內部 BMC)。
在 3.2.2.0 之後有一個術語變更,嘗試將所有頻外管理介面 (iDRAC) 的術語標準化至 BMC。