PowerFlex:SDS 持續取消耦合 MTU 不相符

Summary: SDS 新增至新建立的 DVS (分散式虛擬交換器) 後,會持續進入解耦/中斷連線狀態

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

vCenter 的更新失敗,並部署了新的 vCenter 執行個體。現有的 SVM 已新增至新的 vCenter,然後是新建立的 DVS (分散式虛擬交換器)。完成此作業後,一個 SDS 會繼續進入分離/中斷連線狀態。SDS 顯示為已中斷連線、連線待處理 scli --query_all_sds 產量:

SDS ID: b7g3bd870000000aName: SIO-ESX1 State: Disconnected, Join-Pending IP: 172.21.55.110 Port: 7072 Version: 2.0.13000

MDM 事件記錄顯示 SDS 持續解耦、進入冷卻模式,然後重新連線。

2017-10-09 12:35:53.155 SDS_DECOUPLED ERROR SDS: SIO-ESX1 (id b7g3bd870000000a) decoupled. 2017-10-09 12:35:53.156 SDS_IN_COOL_DOWN WARNING 
SDS: SIO-ESX1 (ID b7g3bd870000000a) will disconnect from MDM for 15 seconds failed to reconnect multiple times 2017-10-09 12:36:08.155 
SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:36:13.161 SDS_RECONNECTED INFO SDS: SIO-ESX1 
(ID b7g3bd870000000a) reconnected 2017-10-09 12:36:18.255 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 
2017-10-09 12:36:23.259 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:36:28.255 SDS_RECONNECTED 
INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected ... 2017-10-09 12:38:41.153 SDS_DECOUPLED ERROR SDS: SIO-ESX1 (id b7g3bd870000000a) 
decoupled. 2017-10-09 12:38:41.155 SDS_IN_COOL_DOWN WARNING SDS: SIO-ESX1 (ID b7g3bd870000000a) will disconnect from MDM for 15 seconds
 failed to reconnect multiple times 2017-10-09 12:38:56.159 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected
 2017-10-09 12:39:01.164 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:39:06.260 SDS_RECONNECTED 
INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:39:11.265 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) 
reconnected

MDM 追蹤記錄顯示 SDS 發生通訊問題。SDS 正在連線,然後中斷連線:

09/10 12:39:11.261955 0x7f66b2a32eb0:tgtMgr_CheckMsgReturnedRC:01728: Message RC is TIMEOUT, RC is COMMUNICATION_ERROR 09/10 12:39:11.261972
 0x7f66b2a32eb0:tgtMgr_ConfigureTgt:05190: TGT_CONFIG Failed to update new TGT b9f3bd870000000a on all other TGTs RC: COMMUNICATION_ERROR
 09/10 12:39:11.261981 0x7f66b2a32eb0:tgtMgr_ProcessComplete:07188: Tgt: b7g3bd870000000a RC=COMMUNICATION_ERROR type: UP upDownState: 
DOWN processState: UP_INPROGRESS mdmTgtConGen: 51897 upPend: 1 downPend: 0 devErrPend: 0 wasDown: 1 createIP: 0 reconstructIP: 0 09/10
 12:39:11.261994 0x7f66b2a32eb0:keepalive_SetTgtFenced:00331: TGT: b7g3bd870000000a 09/10 12:39:11.262015 0x7f66b0902eb0:repExtent_IO:02976:
 Writing the repository to disk and cluster. Extent: 0 Page: 186 Offset: 761856 Size: 65536 09/10 12:39:11.263420 
0x7f66b2a32eb0:tgtMgr_InitiateProcessUnlocked:07027: Tgt: b7g3bd870000000a processType: UP upDownState: DOWN processState: IDLE 
mdmTgtConGen: 51897 upPending: 0 downPending: 0 wasDown: 1 createIP: 0 reconstructIP: 0 aboutToBeRemoved: 0 09/10 12:39:11.263472
 0x7f66b2a71eb0:tgtMgr_HandleWorkReq:04511: TgtId: b7g3bd870000000a starting Up process 09/10 12:39:11.263488 0x7f66b0926eb0:
repExtent_IO:02976: Writing the repository to disk and cluster. Extent: 0 Page: 186 Offset: 761856 Size: 65536 09/10 12:39:11.264680 
0x7f66b2a71eb0:keepalive_SetTgtListenOnly:00377: TGT: b7g3bd870000000a 09/10 12:39:11.264689 0x7f66b2a71eb0:mdmTgtMsg_SendSyncAddMdm:00505
: TGT_CONFIG TgtId: b7g3bd870000000a MdmId: 47e9330a1b66a52e mdmTgtConnectionGenNum: 51898 bForceClean: 0 bQuiesce: 0 quiesceGen: 1 
09/10 12:39:11.265081 0x7f66b2a71eb0:mosEventLog_PostInternal:00590: New event added. Message: "SDS: SIO-ESX (ID b7g3bd870000000a) 
reconnected". Additional info: "" Severity: Info 09/10 12:39:11.265091 0x7f66b2a71eb0:mdmTgtMsg_SendReconfStart:00571: TGT_CONFIG 
TgtId: b7g3bd870000000a

Cause

DVS (分散式虛擬交換器) 上的其中一個上行鏈路設定為 1500 MTU,其餘網路元件則設定為 9000 MTU。這會導致 SDS 和 MDM 之間發生通訊問題。

Resolution

這不是 ScaleIO 問題,這是 ESXi 網路組態問題。

編輯 DVS (分散式虛擬交換器) 上行鏈路,並將 MTU 大小設定為 9000,以便與所有網路 MTU 設定保持一致。
確認網路路徑中的所有元件都設為 9000 MTU。

Affected Products

VxFlex Product Family

Products

VxFlex Product Family
Article Properties
Article Number: 000050238
Article Type: Solution
Last Modified: 17 Apr 2026
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.