Connectrix Brocade B 系列:DS-6520B 交换机内核死机:哎呀:内核模式异常,sig:5 [#1]

Summary: 交换机将死机,或者交换机可以挂起而不会死机。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



由于以下字符串之一,交换机死机(问题的堆栈跟踪可能会有所不同) 在堆栈跟踪中查找下面突出显示的行,以验证您是否遇到了已知问题。 Errdump: [HAM-1004], 35107/3919, 机箱, 信息, 交换机名称, 处理器重新启动 - 软件故障:内核死机,重新启动.c,ppc_booke_sw_wdt_heartbeat drivers/char/watchdog/booke_wdt.c:120 中的内核错误! PDSHOW: 哎呀:内核模式异常,sig:5 [#1] 咬:401416A0 LR:401416A0 SP:40313760 REGS:403136b0 TRAP:0700 DBCR0:000000000 Tainted:P    Msr:00021200 EE:0 PR:0 FP:0 ME:1 IR/DR:00 TASK = 402cf750[0] 'swapper' THREAD:40310000 Last syscall:120 GPR00:401416A0 40313760 402CF750 00000004 00000001 00000000 00000000 00000000 GPR08:402D0000 00021200 00000000 4030D3F0 00000000 10019C14 C262ADB8 C2630000 GPR16的:00000000 00000000 C7600000 00000620 00000001 C8010000 40335300 40340000 GPR24的:40330000 40340000 00001234 28002222 40330000 40330000 403137B0 40330000 NIP [401416a0] ppc_booke_sw_wdt_heartbeat+0xc0/0xc8 LR [401416a0] ppc_booke_sw_wdt_heartbeat+0xc0/0xc8 调用跟踪:  40313770 [40004618] timer_interrupt+0x1c4/0x208  403137a0 [40002b4c] ret_from_except+0x0/0x18  40313860 [c251fcc4]c3_rte_error_handler+0x25c/0x978 [condor3_module]  403138F0 [C23CCA84] c3_rte_error_intr_service+0x124/0x1dc [condor3_module]  40313960 [c23d1cac] c3_error_intr_service+0x127c/0x2fcc [condor3_module]  40313c70 [c23d5df0] c3_intr_handler+0x3a4/0x6f8 [condor3_module]  40313D10 [C23E3E3C] c3_hi_service+0x7c/0x7a8 [condor3_module]  40313DB0 [C23E468C] asic_c3_hi_service+0x124/0x19c [condor3_module]  40313dd0 [c2598b64] asic_hi_tasklet+0xb4/0x108 [condor3_module]  40313e00 [400270b8] tasklet_hi_action+0x78/0xe4  40313e20 [40026b80] __do_softirq+0xb0/0x148  40313e60 [40026c70] do_softirq+0x58/0x60  40313e70 [400044f4] timer_interrupt+0xa0/0x208  40313ea0 [40002b4c] ret_from_except+0x0/0x18  40313f60 [4026d8a8] schedule+0x668/0x75c  40313FA0 [400042CC] default_idle+0x38/0x48  40313fb0 [40004304] cpu_idle+0x28/0x44  40313fc0 [40001928] rest_init+0x28/0x38  40313FD0 [40314674] start_kernel+0x170/0x1a8  40313ff0 [40000370] skpinv+0x2a0/0x2dc 下一个 sp 0!   对于同一问题,堆栈跟踪中存在另外两个可能的差异: LR [401414cc] ppc_booke_sw_wdt_heartbeat+0xc0/0xc8 调用跟踪:_  92227620 [40004618] _timer_interrupt+0x1c4/0x208  92227650 [40002b4c] _ret_from_except+0x0/0x18  92227710 [c1b27594] _c3_edb_error_intr_service+0x28/0xd04 [condor3_module]  922277b0 [c19a308c] _c3_error_intr_service+0xee8/0x2fcc [condor3_module]  92227ac0 [c19a73d4] _c3_intr_handler+0x3a4/0x6f8 [condor3_module]  92227b60 [c19b5180] _c3_hi_service+0x7c/0x754 [condor3_module]  92227c00 [c19b597c] _asic_c3_hi_service+0x124/0x19c [condor3_module]  92227c20 [c1b5b598] _asic_hi_tasklet+0xb4/0x108 [condor3_module]  92227c50 [400270b8] _tasklet_hi_action+0x78/0xe4  92227c70 [40026b80] ___do_softirq+0xb0/0x148 NIP [401416a0] ppc_booke_sw_wdt_heartbeat+0xc0/0xc8 LR [401416a0] ppc_booke_sw_wdt_heartbeat+0xc0/0xc8 调用跟踪:  89a275a0 [40004618] timer_interrupt+0x1c4/0x208  89a275d0 [40002b4c] ret_from_except+0x0/0x18  89a27690 [c24e9800] c3_ftb_drp_dps_update_from_cache+0x4c/0x220 [condor3_module]  89a276d0 [c24e9c88] c3_ftb_drp_dps_perr_recov+0x1c4/0x204 [condor3_module]  89a276f0 [c24e9eac] c3_ftb_parity_recov+0xd0/0xf4 [condor3_module]  89a27720 [c23cd08c] c3_ftb_error_intr_service+0x1a4/0x24c [condor3_module]  89a27790 [c23d1cfc] c3_error_intr_service+0x12cc/0x2fcc [condor3_module]  89a27aa0 [c23d5df0] c3_intr_handler+0x3a4/0x6f8 [condor3_module]  89a27b40 [c23e3e3c] c3_hi_service+0x7c/0x7a8 [condor3_module]  89a27be0 [c23e468c] asic_c3_hi_service+0x124/0x19c [condor3_module]  89a27c00 [c2598b64] asic_hi_tasklet+0xb4/0x108 [condor3_module]  89a27c30 [400270b8] tasklet_hi_action+0x78/0xe4  89a27c50 [40026b80] __do_softirq+0xb0/0x148  89a27c90 [40026c70] do_softirq+0x58/0x60

Cause

临时奇偶校验错误使 CPU 停滞,导致死机。

这仅影响具有 MPC8548(即 DS-6520B 交换机)的基于 C3 的平台。

这是 Brocade DEFECT000623098。

Resolution

修复:
升级到 Fabric OS 8.1.0、8.0.2a、7.4.2 和 7.4.1-CEE-e3。

截至 2017 年 5 月,Dell EMC 已发布 Fabric OS 8.1.0a 和 7.4.2,其中包括此缺陷的修复程序。

Affected Products

Connectrix

Products

Connectrix B-Series Hardware
Article Properties
Article Number: 000054774
Article Type: Solution
Last Modified: 18 Sep 2025