Connectrix: Cisco - Sysmgr flygtig hukommelse fulde meddelelser
Summary: Dette problem opleves normalt, når der er en hukommelseslækage . Loglogoutputtet oversvømmes med komplette meddelelser i databasen
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Sys Manager flygtig hukommelse fulde meddelelser
Cause
Følgende type syslog-meddelelser logføres i Vis loglogføringsloghændelser:
Fejlmeddelelse:show logging log2019 May 10 07:37:29 switchname %SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is unexpectedly high at 84%.2019 May 10 07:40:29 switchname %SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is unexpectedly high at 84%.2019 May 10 07:43:29 switchname %SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is unexpectedly high at 84%.
show system internal flash
Mount-on 1K-blocks Used Available Use% Filesystem
/proc 0 0 0 0 proc
/sys 0 0 0 0 none
/debugfs 0 0 0 0 nodev
/isan 512000 274416 237584 54 none
/var 51200 472 50728 1 none
/nxos/tmp 20480 1216 19264 6 none
/var/log 51200 1976 49224 4 none
/var/home 5120 0 5120 0 none
/var/tmp 307200 400 306800 1 none
/var/sysmgr 307200 4 307196 1 none
/var/sysmgr/ftp 307200 76 307124 1 none
/dev/shm 204800 172568 32232 85 none
/volatile 204800 36 204764 1 none
/debug 2048 32 2016 2 none
/lc 512000 53416 458584 11 none
Resolution
Dette problem peger på Cisco-fejl-id CSCvj70275.
Permanent rettelse:
Opgrader MDS-switchene til 8.3.x
Additional Information
BEMÆRK : Cisco har bekræftet, at ovenstående fejl-id også henviser til MDS 9000-modeller.