Connectrix: Cisco – Sysmgr -meddelanden om fullständigt flyktigt minne
Summary: Det här problemet upplevs vanligtvis när det finns en minnesläcka . Loggningsloggens utdata översvämmas av databasfullständiga meddelanden
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Meddelanden om fullt minne i Sys Manager
Cause
Följande typ av syslog-meddelanden loggas i logghändelserna för showloggning:
Felmeddelande:show logging log2019 May 10 07:37:29 switchname %SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is unexpectedly high at 84%.2019 May 10 07:40:29 switchname %SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is unexpectedly high at 84%.2019 May 10 07:43:29 switchname %SYSMGR-2-VOLATILE_DB_FULL: System volatile database usage is unexpectedly high at 84%.
show system internal flash
Mount-on 1K-blocks Used Available Use% Filesystem
/proc 0 0 0 0 proc
/sys 0 0 0 0 none
/debugfs 0 0 0 0 nodev
/isan 512000 274416 237584 54 none
/var 51200 472 50728 1 none
/nxos/tmp 20480 1216 19264 6 none
/var/log 51200 1976 49224 4 none
/var/home 5120 0 5120 0 none
/var/tmp 307200 400 306800 1 none
/var/sysmgr 307200 4 307196 1 none
/var/sysmgr/ftp 307200 76 307124 1 none
/dev/shm 204800 172568 32232 85 none
/volatile 204800 36 204764 1 none
/debug 2048 32 2016 2 none
/lc 512000 53416 458584 11 none
Resolution
Det här problemet pekar på Cisco-bugg-ID CSCvj70275.
Permanent korrigering:
Uppgradera MDS-switcharna till 8.3.x
Additional Information
Obs! Cisco har bekräftat att ovanstående bugg-ID även avser MDS 9000-modeller.