Data Domain: High failure rate seen on HERA NVRAM module
Summary: This Article acknowledges reliability issues seen on the 'HERA' NVRAM module installed within certain Data Domain (DD) models.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Applies to:
- DD6300 / DD6800 / DD9300 / DD9500 / DD9800 (all running HERA NVRAM Module)
- DDOS versions
- Data Domain Operating System 6.0: 6.0.2.40 or earlier
Data Domain Operating System 6.1: 6.1.2.30 or earlier
Data Domain Operating System 6.2: 6.2.0.10 or earlier
- Data Domain Operating System 6.0: 6.0.2.40 or earlier
Symptoms:
- A higher than expected failure rate of the 8GB NVRAM (HERA) module is being encountered.
Cause
The root cause of these NVRAM Module failures has been determined (DTA 533489).
A software update has been made available for the affected models.
Resolution
If the system has reported an NVRAM failure with a single correctable error, the Filesystem is disabled (by design).
- Using DD-CLI enter the command:
-
# system show nvram-detailed
-
- Reboot the DD unit and this should clear the single transient fault.
- If the error does not clear by rebooting, replace the NVRAM card
This issue is addressed by DDOS upgrade. See Dell Technical Advisory: DTA 533489
Affected Products
Data DomainProducts
Data Domain, DD6300 Appliance, DD6800 Appliance, DD9300 Appliance, DD9500 Appliance, DD9800 ApplianceArticle Properties
Article Number: 000056993
Article Type: Solution
Last Modified: 17 Apr 2026
Version: 8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.