Symptoms
A customers Unity Array may call home and report a file system offline condition.
Customer's production services may be impacted as a result.
Clarify Id: Vendor: DeviceType: Unity Model: SerialNumber: EmbedLevel: 1 InternalMaxSize: 0 Ucode_Ver: IP_Address: Not Available ConnectNum: UDoctorKH01.40 SymptomCode: neo14:600f4 Category: status Severity: Critical Status: Failed Component: Health FirstTime: LastTime: CDATA: Device: spa <CustomerContactInfo> <CustomerInfo> <admin> <admin_email> <admin_name> <admin_number> </admin> <company> <company_address> </company_address> <company_name> </company> </CustomerInfo> </CustomerContactInfo>
Description:
File system XXXXXX is offline.
Cause
The issue is that the file system goes offline with freeing free block error, this is the meta space of the lower deck file system.
Resolution
Contact Dell Customer Service And request immediate recovery assistance if your file system is offline.
Permanent Fix:
- The issue is fixed in the 5.0.2.0.5.009 code. After recovery, upgrade to 5.0.2.0.5.009 or later to have the fix and prevent reoccurrence.
Workaround:
- There is no workaround for this problem.