Connectrix Cisco: Switchen er slukket på grund af kernelpanik
Summary: MDS-switchen var nede og blev ikke genindlæst efter kernelpanik. En bruger skulle tænde kontakten manuelt.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Output fra Stack-Trace viser kun fem ud af seks CPU'er online, fordi Switch var offline og ikke blev genindlæst.
`show system reset-reason` ----- reset reason for module 1 (from Supervisor in slot 1) --- 1) At 65175 usecs after Tue Oct 13 02:48:39 2020 Reason: Kernel Panic Service: Version: 8.1(1a) ‘show logging nvram’ 2020 Oct 14 18:44:02.277 switch %SYSLOG-2-SYSTEM_MSG : Syslogs wont be logged into logflash until logflash is online 2020 Oct 14 18:44:05.851 switch %KERN-0-SYSTEM_MSG: [ 0.036807] Host controller irq 55 - kernel 2020 Oct 14 18:44:05.880 switch %KERN-0-SYSTEM_MSG: [ 0.057612] Assign root port irq 55 - kernel 2020 Oct 14 18:44:05.881 switch %KERN-0-SYSTEM_MSG: [ 0.057633] Host controller irq 54 - kernel 2020 Oct 14 18:44:05.883 switch %KERN-0-SYSTEM_MSG: [ 0.059007] Assign root port irq 54 - kernel 2020 Oct 14 18:44:05.912 switch %KERN-0-SYSTEM_MSG: [ 0.774555] Enabling all PCI devices - kernel ‘show logging onboard module stack-trace’ CPU 0 Call Trace: [b0463bc4] do_raw_spin_lock+0xec/0x120(unreliable) [b0698738] dev_watchdog+0x58/0x29c [b04324c4] call_timer_fn+0x48/0xfc [b0432770] run_timer_softirq+0x1f4/0x248 [b042af38] __do_softirq+0x16c/0x368 [b042b428] irq_exit+0x68/0x90 [b040a3c8] timer_interrupt+0x204/0x278 [b040f388] ret_from_except+0x0/0x18 CPU 1 Process: swapper/1 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 2 Process: sysinfo (pid 3855) Call Trace: [b0480d58] smp_call_function_many+0x268/0x274(unreliable) [b04182f8] flush_tlb_mm+0x58/0x68 [b042532c] copy_process.part.69+0xbb0/0x11a0 [b0425a84] do_fork+0xd0/0x318 [b040ecac] ret_from_syscall+0x0/0x3c CPU 3 Process: swapper/3 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 4 Process: swapper/4 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48
Cause
En af CPU'erne var offline, hvilket fik kontakten til at slukke.
Resolution
Permanent løsning:
- Hvis alle seks CPU'er ikke er online, skal du udskifte switchen og sikre dig, at den nye switch kører på NX-OS v8.4(1a) eller nyere.
- Hvis alle seks CPU'er er online, skal du opgradere firmwaren til NX-OS v8.4 (1a) eller nyere for at undgå gentagelse.
Additional Information
Dette gælder kun for Cisco MDS-9396s-switche.
Affected Products
Connectrix MDS 9396SArticle Properties