Symptoms
A saída do Stack-Trace mostra apenas cinco das seis CPUs on-line devido às quais o Switch estava off-line e não foi recarregado.
`show system reset-reason` ----- reset reason for module 1 (from Supervisor in slot 1) --- 1) At 65175 usecs after Tue Oct 13 02:48:39 2020 Reason: Kernel Panic Service: Version: 8.1(1a) ‘show logging nvram’ 2020 Oct 14 18:44:02.277 switch %SYSLOG-2-SYSTEM_MSG : Syslogs wont be logged into logflash until logflash is online 2020 Oct 14 18:44:05.851 switch %KERN-0-SYSTEM_MSG: [ 0.036807] Host controller irq 55 - kernel 2020 Oct 14 18:44:05.880 switch %KERN-0-SYSTEM_MSG: [ 0.057612] Assign root port irq 55 - kernel 2020 Oct 14 18:44:05.881 switch %KERN-0-SYSTEM_MSG: [ 0.057633] Host controller irq 54 - kernel 2020 Oct 14 18:44:05.883 switch %KERN-0-SYSTEM_MSG: [ 0.059007] Assign root port irq 54 - kernel 2020 Oct 14 18:44:05.912 switch %KERN-0-SYSTEM_MSG: [ 0.774555] Enabling all PCI devices - kernel ‘show logging onboard module stack-trace’ CPU 0 Call Trace: [b0463bc4] do_raw_spin_lock+0xec/0x120(unreliable) [b0698738] dev_watchdog+0x58/0x29c [b04324c4] call_timer_fn+0x48/0xfc [b0432770] run_timer_softirq+0x1f4/0x248 [b042af38] __do_softirq+0x16c/0x368 [b042b428] irq_exit+0x68/0x90 [b040a3c8] timer_interrupt+0x204/0x278 [b040f388] ret_from_except+0x0/0x18 CPU 1 Process: swapper/1 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 2 Process: sysinfo (pid 3855) Call Trace: [b0480d58] smp_call_function_many+0x268/0x274(unreliable) [b04182f8] flush_tlb_mm+0x58/0x68 [b042532c] copy_process.part.69+0xbb0/0x11a0 [b0425a84] do_fork+0xd0/0x318 [b040ecac] ret_from_syscall+0x0/0x3c CPU 3 Process: swapper/3 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 4 Process: swapper/4 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48
Cause
Uma das CPUs estava off-line, o que fazia com que o switch desligasse.
Resolution
Correção permanente:
- Se todas as seis CPUs não estiverem on-line, substitua o switch e certifique-se de que o novo switch esteja em execução no NX-OS v8.4(1a) ou posterior.
- Se todas as seis CPUs estiverem on-line, faça upgrade do firmware para NX-OS v8.4(1a) ou posterior para evitar novas ocorrências.
Additional Information
Isso é aplicável somente para switches Cisco MDS-9396s.