Connectrix Cisco Switchen stängs av på grund av kernelpanik

Summary: MDS-switchen låg nere och laddades inte om efter kernelpanik. En användare var tvungen att slå PÅ switchen manuellt.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Utdata från Stack-Trace visar endast fem av sex CPU:er online på grund av vilken Switch som var offline och inte laddades om.

`show system reset-reason`
----- reset reason for module 1 (from Supervisor in slot 1) ---
1) At 65175 usecs after Tue Oct 13 02:48:39 2020
    Reason: Kernel Panic
    Service:
    Version: 8.1(1a)

‘show logging nvram’
2020 Oct 14 18:44:02.277 switch %SYSLOG-2-SYSTEM_MSG : Syslogs wont be logged into logflash until logflash is online
2020 Oct 14 18:44:05.851 switch %KERN-0-SYSTEM_MSG: [    0.036807] Host controller irq 55 - kernel
2020 Oct 14 18:44:05.880 switch %KERN-0-SYSTEM_MSG: [    0.057612] Assign root port irq 55 - kernel
2020 Oct 14 18:44:05.881 switch %KERN-0-SYSTEM_MSG: [    0.057633] Host controller irq 54 - kernel
2020 Oct 14 18:44:05.883 switch %KERN-0-SYSTEM_MSG: [    0.059007] Assign root port irq 54 - kernel
2020 Oct 14 18:44:05.912 switch %KERN-0-SYSTEM_MSG: [    0.774555] Enabling all PCI devices - kernel

‘show logging onboard module stack-trace’
CPU 0
Call Trace:
[b0463bc4] do_raw_spin_lock+0xec/0x120(unreliable)
[b0698738] dev_watchdog+0x58/0x29c
[b04324c4] call_timer_fn+0x48/0xfc
[b0432770] run_timer_softirq+0x1f4/0x248
[b042af38] __do_softirq+0x16c/0x368
[b042b428] irq_exit+0x68/0x90
[b040a3c8] timer_interrupt+0x204/0x278
[b040f388] ret_from_except+0x0/0x18

CPU 1   Process: swapper/1 (pid 0)
Call Trace:
[b04230a4] cpm_idle_wait+0x14/0x24(unreliable)
[b0469d4c] cpu_startup_entry+0x124/0x1e8
[b0410d78] start_secondary+0x1fc/0x200
[b0402234] start_secondary_47x+0x24/0x48

CPU 2   Process: sysinfo (pid 3855)
Call Trace:
[b0480d58] smp_call_function_many+0x268/0x274(unreliable)
[b04182f8] flush_tlb_mm+0x58/0x68
[b042532c] copy_process.part.69+0xbb0/0x11a0
[b0425a84] do_fork+0xd0/0x318
[b040ecac] ret_from_syscall+0x0/0x3c

CPU 3   Process: swapper/3 (pid 0)
Call Trace:
[b04230a4] cpm_idle_wait+0x14/0x24(unreliable)
[b0469d4c] cpu_startup_entry+0x124/0x1e8
[b0410d78] start_secondary+0x1fc/0x200
[b0402234] start_secondary_47x+0x24/0x48

CPU 4   Process: swapper/4 (pid 0)
Call Trace:
[b04230a4] cpm_idle_wait+0x14/0x24(unreliable)
[b0469d4c] cpu_startup_entry+0x124/0x1e8
[b0410d78] start_secondary+0x1fc/0x200
[b0402234] start_secondary_47x+0x24/0x48

 

Cause

En av processorerna var offline vilket fick switchen att stängas av.

 

Resolution

Permanent lösning:

  • Om alla sex processorerna inte är online byter du ut switchen och kontrollerar att den nya switchen körs på NX-OS v8.4(1a) eller senare.
  • Om alla sex processorerna är online uppgraderar du den fasta programvaran till NX-OS v8.4(1a) eller senare för att undvika att det upprepas.

 

Additional Information

Detta gäller endast för Cisco MDS-9396s-switchar.

 

Affected Products

Connectrix MDS 9396S
Article Properties
Article Number: 000181486
Article Type: Solution
Last Modified: 03 Apr 2026
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.