Connectrix Cisco:由於核心錯誤,交換器已關閉電源

Summary: MDS 交換器已關閉,且未在核心錯誤後重新載入。使用者必須手動開啟交換器電源。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

堆疊追蹤的輸出顯示只有六顆 CPU 中有五顆處於線上狀態,因此交換器處於離線狀態,且未重新載入。

`show system reset-reason`
----- reset reason for module 1 (from Supervisor in slot 1) ---
1) At 65175 usecs after Tue Oct 13 02:48:39 2020
    Reason: Kernel Panic
    Service:
    Version: 8.1(1a)

‘show logging nvram’
2020 Oct 14 18:44:02.277 switch %SYSLOG-2-SYSTEM_MSG : Syslogs wont be logged into logflash until logflash is online
2020 Oct 14 18:44:05.851 switch %KERN-0-SYSTEM_MSG: [    0.036807] Host controller irq 55 - kernel
2020 Oct 14 18:44:05.880 switch %KERN-0-SYSTEM_MSG: [    0.057612] Assign root port irq 55 - kernel
2020 Oct 14 18:44:05.881 switch %KERN-0-SYSTEM_MSG: [    0.057633] Host controller irq 54 - kernel
2020 Oct 14 18:44:05.883 switch %KERN-0-SYSTEM_MSG: [    0.059007] Assign root port irq 54 - kernel
2020 Oct 14 18:44:05.912 switch %KERN-0-SYSTEM_MSG: [    0.774555] Enabling all PCI devices - kernel

‘show logging onboard module stack-trace’
CPU 0
Call Trace:
[b0463bc4] do_raw_spin_lock+0xec/0x120(unreliable)
[b0698738] dev_watchdog+0x58/0x29c
[b04324c4] call_timer_fn+0x48/0xfc
[b0432770] run_timer_softirq+0x1f4/0x248
[b042af38] __do_softirq+0x16c/0x368
[b042b428] irq_exit+0x68/0x90
[b040a3c8] timer_interrupt+0x204/0x278
[b040f388] ret_from_except+0x0/0x18

CPU 1   Process: swapper/1 (pid 0)
Call Trace:
[b04230a4] cpm_idle_wait+0x14/0x24(unreliable)
[b0469d4c] cpu_startup_entry+0x124/0x1e8
[b0410d78] start_secondary+0x1fc/0x200
[b0402234] start_secondary_47x+0x24/0x48

CPU 2   Process: sysinfo (pid 3855)
Call Trace:
[b0480d58] smp_call_function_many+0x268/0x274(unreliable)
[b04182f8] flush_tlb_mm+0x58/0x68
[b042532c] copy_process.part.69+0xbb0/0x11a0
[b0425a84] do_fork+0xd0/0x318
[b040ecac] ret_from_syscall+0x0/0x3c

CPU 3   Process: swapper/3 (pid 0)
Call Trace:
[b04230a4] cpm_idle_wait+0x14/0x24(unreliable)
[b0469d4c] cpu_startup_entry+0x124/0x1e8
[b0410d78] start_secondary+0x1fc/0x200
[b0402234] start_secondary_47x+0x24/0x48

CPU 4   Process: swapper/4 (pid 0)
Call Trace:
[b04230a4] cpm_idle_wait+0x14/0x24(unreliable)
[b0469d4c] cpu_startup_entry+0x124/0x1e8
[b0410d78] start_secondary+0x1fc/0x200
[b0402234] start_secondary_47x+0x24/0x48

 

Cause

其中一個 CPU 離線,導致交換器關閉電源。

 

Resolution

永久修正:

  • 如果全部六個 CPU 未連線,請更換交換器,並確保新交換器執行的是 NX-OS v8.4(1a) 或更新版本。
  • 如果全部六個 CPU 均在線上,請將韌體升級至 NX-OS v8.4(1a) 或更新版本,以避免再次發生。

 

Additional Information

這僅適用於 Cisco MDS-9396s 交換器

 

Affected Products

Connectrix MDS 9396S
Article Properties
Article Number: 000181486
Article Type: Solution
Last Modified: 03 Apr 2026
Version:  2