Connectrix Cisco:由於核心錯誤,交換器已關閉電源
Summary: MDS 交換器已關閉,且未在核心錯誤後重新載入。使用者必須手動開啟交換器電源。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
堆疊追蹤的輸出顯示只有六顆 CPU 中有五顆處於線上狀態,因此交換器處於離線狀態,且未重新載入。
`show system reset-reason` ----- reset reason for module 1 (from Supervisor in slot 1) --- 1) At 65175 usecs after Tue Oct 13 02:48:39 2020 Reason: Kernel Panic Service: Version: 8.1(1a) ‘show logging nvram’ 2020 Oct 14 18:44:02.277 switch %SYSLOG-2-SYSTEM_MSG : Syslogs wont be logged into logflash until logflash is online 2020 Oct 14 18:44:05.851 switch %KERN-0-SYSTEM_MSG: [ 0.036807] Host controller irq 55 - kernel 2020 Oct 14 18:44:05.880 switch %KERN-0-SYSTEM_MSG: [ 0.057612] Assign root port irq 55 - kernel 2020 Oct 14 18:44:05.881 switch %KERN-0-SYSTEM_MSG: [ 0.057633] Host controller irq 54 - kernel 2020 Oct 14 18:44:05.883 switch %KERN-0-SYSTEM_MSG: [ 0.059007] Assign root port irq 54 - kernel 2020 Oct 14 18:44:05.912 switch %KERN-0-SYSTEM_MSG: [ 0.774555] Enabling all PCI devices - kernel ‘show logging onboard module stack-trace’ CPU 0 Call Trace: [b0463bc4] do_raw_spin_lock+0xec/0x120(unreliable) [b0698738] dev_watchdog+0x58/0x29c [b04324c4] call_timer_fn+0x48/0xfc [b0432770] run_timer_softirq+0x1f4/0x248 [b042af38] __do_softirq+0x16c/0x368 [b042b428] irq_exit+0x68/0x90 [b040a3c8] timer_interrupt+0x204/0x278 [b040f388] ret_from_except+0x0/0x18 CPU 1 Process: swapper/1 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 2 Process: sysinfo (pid 3855) Call Trace: [b0480d58] smp_call_function_many+0x268/0x274(unreliable) [b04182f8] flush_tlb_mm+0x58/0x68 [b042532c] copy_process.part.69+0xbb0/0x11a0 [b0425a84] do_fork+0xd0/0x318 [b040ecac] ret_from_syscall+0x0/0x3c CPU 3 Process: swapper/3 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 4 Process: swapper/4 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48
Cause
其中一個 CPU 離線,導致交換器關閉電源。
Resolution
永久修正:
- 如果全部六個 CPU 未連線,請更換交換器,並確保新交換器執行的是 NX-OS v8.4(1a) 或更新版本。
- 如果全部六個 CPU 均在線上,請將韌體升級至 NX-OS v8.4(1a) 或更新版本,以避免再次發生。
Additional Information
這僅適用於 Cisco MDS-9396s 交換器
Affected Products
Connectrix MDS 9396SArticle Properties
Article Number: 000181486
Article Type: Solution
Last Modified: 03 Apr 2026
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.