DLm mainframe batch job abends with S522 with or without DLm Guaranteed Replication enabled

Summary: DLm Guaranteed Replication may not be causing or contributing to a job with a S522 abend.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms


 06.30.06 JOB04931  IEF403I SA70HQ98 - STARTED - TIME=06.30.06                                                                       
 06.43.04 JOB04931  -                                      -----TIMINGS (MINS.)------                          -----PAGING COUNTS----
 06.43.04 JOB04931  -STEPNAME PROCSTEP    RC   EXCP   CONN       TCB       SRB  CLOCK          SERV  WORKLOAD  PAGE  SWAP   VIO SWAPS
 06.43.04 JOB04931  -J010     S010        00      9      8       .00       .00   12.9            35  BAT          0     0     0     0
 06.43.04 JOB04931 *IEF233A M 0281,PRIVAT,SL,SA70HQ98,S020                                                                           
 06.43.04 JOB04931 *TMS001  IEF233A M 0281,PRIVAT,SL,SA70HQ98,S020,HQ.SA7098.S070F01.TRIGGER.BKUP.G1631V00                           
 06.43.05 JOB04931  IECTMS9 0281,A74406,SA70HQ98,DFSOLOG ,CATALOG   ,00001,GER.BKUP.G1631V00                                         
 06.43.05 JOB04931  IEC705I TAPE ON 0281,A74406,SL,COMP,SA70HQ98,S020.J010,MEDIA2                                                    
 06.43.05 JOB04931  IEC130I DIAGNOSE DD STATEMENT MISSING                                                                            
 06.43.05 JOB04931  IEC130I DIAGNOSE DD STATEMENT MISSING                                                                            
 06.53.55 JOB04931  IEA995I SYMPTOM DUMP OUTPUT  919                                                                                 
    919             SYSTEM COMPLETION CODE=522                                                                                       
    919              TIME=06.53.55  SEQ=60863  CPU=0000  ASID=00B0                                                                   
    919              PSW AT TIME OF ERROR  070C1000   85FA5A2C  ILC 2  INTC 01                                                       
    919                NO ACTIVE MODULE FOUND                                                                                        
    919                NAME=UNKNOWN                                                                                                  
    919                DATA AT PSW  05FA5A26 - 00711311  0A014100  00840A3C                                                          
    919                GR 0: 80000001   1: FF833584                                                                                  
    919                   2: 21672438   3: 007CC950                                                                                  
    919                   4: 007FE990   5: 007FF7C8                                                                                  
    919                   6: 85FA20E0   7: 21672318                                                                                  
    919                   8: 05FA5AF8   9: 80000000                                                                                  
    919                   A: 05FA43AE   B: 00FB5090                                                                                  
    919                   C: 85FA4AC0   D: 007CC450                                                                                  
    919                   E: 85FA4BB8   F: 00000000                                                                                  
    919              END OF SYMPTOM DUMP                                                                                             
 06.53.55 JOB04931  IEC205I DFSOLOG,SA70HQ98,S020,FILESEQ=1, COMPLETE VOLUME LIST,  920                                              
    920             VOLS=A74406

The DLm VTE logs show no indication or error or warning.  
                                                               

Cause

The S522 abend is not a typical job time exceeded error, it's a job wait time exceeded.  That is to say, the time allocated to wait in an SVC wait state was exceeded.  

Resolution

A DLm Guaranteed Replication (GR) timeout exceeded condition will result in a Unit Check being returned to the mainframe job.  The S522 abend is a different scenario.  

Look for data set in use, hardware level enqueue or contention while the job is executing, possibly coming from system backups, migration or recall activity which could be occurring during job execution.  Optionally add TIME= to the JCL EXEC statement.  If unable to find a cause, open a service request with the mainframe support vendor. 

The job wait time parameter is controlled via the SMFPRMxx parmlib member, parameter JWT.    

Affected Products

DD for DLm8100, Disk Library for mainframe DLm2000, Disk Library for mainframe DLm2500, Disk Library for mainframe DLm6000, Disk Library for mainframe DLm8000, Disk Library for mainframe DLm8100, Disk Library for mainframe DLm8500, VNX for DLm2000 , VNX for DLm2100, VNX for DLm6000 ...

Products

VNX for DLm8100
Article Properties
Article Number: 000196766
Article Type: Solution
Last Modified: 13 May 2026
Version:  6